Change Program Master

9

Change Program Master

This procedure replaces the old Program Master by a new one. The old Program
Master is thereby voided from the SiPass standalone memory and the new badge
is declared as Program Master instead. This is helpful if e.g. an other Program
Master than the normal one was added to the memory during wake-up.
Present the new Program Master a further 5 times to step through the remaining
steps, back to Normal mode.

Normal
mode

Read

Open

Closed

Night lock

Add

Void

Program

Read

Open

Closed

Night lock

Add

Void

Program

Read

Open

Closed

Night lock

Add

Void

Program

Old Prog. Master

Read

Open

Closed

Night lock

Add

Void

Program

New Prog. Master

Old Prog. Master

Enter
Program Mode

Declare new
Program Master,
enter Void Mode

Void old
Program Master,
enter Add Mode

Fig. 4

Change Program Master

Any new / unknown badge can be declared as new Program Master.

If change Program Master function is not desired, just present the old Program
Master again the necessary number of times to get to the desired programming
step.