beautypg.com

Schumacher PS-5250 User Manual

Page 10

background image

10

If a problem does occur, check the following:

PROBLEM

POSSIBLE CAUSE

SOLUTION

No Meter Reading

Clips are not making

Rock clips back and forth for a better

(AC Cord Unplugged)

a good connection.

connection.

Battery voltage is too low.

Plug AC line into outlet.
Meter should now indicate.

2 amp charge rate being used.

None, meter will not indicate here.

Charger will not turn

AC outlet is dead.

Plug in a lamp to check for voltage.

on when properly connected.

Poor electrical connection.

Check connections, rock back and forth
for a better connection.

Clicking noise from charger.

Circuit breaker is cycling.

May be in the wrong switch position

Battery is defective.

Have Battery checked.

Severely discharged battery

Allow charging to continue until battery has a

but otherwise a good battery.

chance to recover sufficiently to take a charge.
If more than 20 min. stop charging and have
the battery checked.

Reverse connections at battery.

Shut off charger and correct lead connections.