PROBLEM

REASON

SOLUTION

Alarm is on.

(continued)

Display shows voltage in

between 10.5 and 11.0V.

Display shows . 12V

voltage is too high.

Display shows .Device

demands more than the

inverter’s continuous

power rating.

Display shows .

Inverter is too hot.

12V battery is low.

Recharge/replace battery.

The inverter will automatically shut off

after battery voltage reaches 10.5V.

If in a vehicle, repair/replace the

alternator or charging system.

Use a properly sized and rated 12V

battery.

If the input voltage returns to 15V or

less, the inverter will automatically

restart.

Cycle the inverter power OFF

and ON.

If problem persists, use a larger

inverter or a smaller device.

Increase the ventilation to the

inverter.

Move the inverter to a cooler area.

Reduce the power consumption

of the device. The inverter will

automatically reset after cooling.

Inverter does

not turn on.

Poor contact at terminals.

Fuse is blown.

Inverter may be defective.

Check for poor connection to

battery or power supply. Make sure

connection points are clean. Rock

clamps back and forth for a better

connection.

A blown fuse is usually caused by

reverse polarity or a short circuit

within the inverter.

To replace, contact a qualified

service technician who will

diagnose the inverter and replace

the fuse(s) with the appropriate

replacement(s).

See warranty and call Customer

Service.