Problem: low or no output voltage – Sears 200.71520 User Manual

Page 7

background image

5

REPLACEMENT PARTS

9.

15 A fuse: - 3900000190
Power cable: 0699000329

TROUBLESHOOTINg

10.

PROBLEM: LOw OR NO OUTPUT VOLTAgE

REASON

SOLUTION

Poor contact at terminal

Unplug and reinsert the Ultra-Slim Travel

Inverter 120.

Equipment being operated is drawing

too much power

Use a higher capacity inverter or do not

use the device.

Inverter is too hot (thermal shut down)

Allow inverter to cool. Check for adequate

ventilation. Reduce the load on the in-

verter to rated continuous power output.

Blown Fuse in Power Cable

A blown fuse is usually caused by reverse

polarity or a short circuit within the device

being operated. To replace:

• Disconnect the device immediately.

• Find the source of the problem and

repair it.

• Install a new 15-amp fuse. Do not

tighten the fuse cap too far; finger tight

is sufficient.

NOTE: Installing a fuse higher than 15-

amps may cause damage to the inverter.

Inverter may be defective

Call 1-800-SEARS-64 for troubleshooting

assistance.