К7, к, К"" к, 1 / к/ ,-к – Sharp INSIGHTRANGEHOOD KB-0333K User Manual
Page 8: Connect wiring, Prepare the hood
WARNING
To reduce the risk of electric shock, make
sure power is switched off at the service panel. Lock or
tag service panel to prevent power from being switched
on accidentally.
1
Connect House Wiring (120 VAC) to hood. Use a piece
of cardboard to protect the cooktop, if necessary.
2
Connect house black to hood black wire, house white to
hood white wire and house ground under Green Ground
Screw. Securely tighten cable clamp onto house wiring.
8
CONNECT WIRING
Non-Ducted Installations Only:
Requires a Performance Ring to be attached to the blower
wheel. The Performance Ring is packed behind the Teflon
®
-
Coated Bottom Cover.
To install ring:
1.
Remove Retaining Ring using a flat blade screwdriver.
Set aside for later. Remove the Blower Wheel by rocking
it side to side and applying a slight force to pull wheel
from motor. Turn the Blower Wheel over.
2
. Slide the Performance Ring onto the Small Diameter
End of the blower wheel and down to the Stop Edge of
the wheel.
3.
Reassemble wheel to motor. Make sure Tab on wheel
fits into one of the Motor Slots.
4
. Push wheel down until it is locked in place. Replace
Retaining Ring from Step 1. Be sure it is within the
upper and lower tabs.
PREPARE THE HOOD
BLOWER
WHEEL
TAB
SECTIONS
SMALL DIAMETER
END
STOP
EDGE
PERFORMANCE RING
MOTOR SLOTS
RETAINING RING
5.
Check that wheel is properly positioned as shown.
Press Sections into place if necessary. Make sure wheel
turns freely.
Note: For information on non-ducted filters, see page 9.