TROUBLE SHOOTING

GAS MODEL

Radiant Sensor(10RS)

Resistance value < 1 Ω

If resistance is infinite, replace Radiant

sensor

Gas Valve(25M01A)

Valve 1-2 : Resistance value 1.2K Ω

Valve 1-3 : Resistance value 0.5K Ω

Valve 4-5 : Resistance value 1.2K Ω

If resistance is infinity, replace Valve

Igniter(101D)

Resistance value 40~400 Ω

If resistance is infinite, replace Igniter

Thermostat (60T21 Hi-Limit)230F-50F

Resistance value < 1 Ω

If resistance is infinity, replace

Thermostat