25

Step 4. FIELD WIRING

Note: The gas valve is set in place and pre-wired

at the factory.

A. SIT and Honeywell Millivolt Wiring

(See Figure 46)

1. Select any of the following optional controls:

unit-mounted burner OFF/ON switch (rocker

switch), wall-mounted switch or the remote

control kit. If unit-mounted ON/OFF control is

selected mount it in the gas valve mounting

bracket.

2. If wall-mounted ON/OFF control is selected

mount it in a convenient location on a wall

near the fireplace.

3. Wire the control within the millivolt control

circuit using the 15 feet of 2 conductor wire

supplied with the unit . Caution: do not

connect the optional wall switch to a 120V

power supply.

4. Alternatively, the appliance may be operated

without the use of the controls indicated in

step 1, solely by manipulating the gas valve

control knob. In order to use this method,

twist the free ends of the two conductor wire

(which would otherwise go to the standard

ON/OFF switch or Optional Switch) together

as shown in Figure 46. Note: Wire is located

inside the control compartment

Note: The supplied 15 feet of 2 conductor wire

has one end of each conductor connected to

the gas valve circuit and the other end of each

conductor placed loose inside the control

compartment.

Figure 46-

Millivolt Wiring Diagram

Field Wired

Factory

Wired

TH

TP

TH

TP

* Optional

Burner Switch

Thermopile

Standard OFF/ON

Switch

Schematic
Representation
Only

• If any of the original wire as supplied must be replaced, it must be replaced with

Type AWM 105 C - 18 gage wire.

* Optional Kits Installed - OFF/ON wall switch, wall thermostat or remote control receiver.

FORCED AIR BLOWER

(FBK-100 provided)

(See Figure 47) -

The blower and blower ON/Off control switch

are factory installed. An electrical outlet box is

also factory installed for the connection of the

electrical power supply to the blower.

1. Route a 3-wire, 120Vac 60Hz 1ph power

line to the lower right rear corner of the

appliance.

2. Connect the black supply wire to the top

outlet's black pigtail lead and to the switch's

black lead. Connect the white supply wire to

the neutral terminal of the outlet box.

3. Connect the ground supply wire to the outlet

box green ground screw as shown.

4. Plug the blower cord into the bottom recep-

tacle of the outlet box.

HT

PT

HT

PT

*

* Twist wires together to operate unit

solely by manipulating the gas valve

control knob; or connect wires to

optional on/off switch or wall switch

or thermostat or remote control to

operate unit.

Figure 47 -

Blower Wiring Diagram

1. If any of the original wire as supplied must be replaced,

1.

it must be replaced with Type AWM 105

°

C – 18 GA. wire.

2. 120V, 60Hz – Less than 3 amps.

Wiring Diagram

Showing the Blower Wiring

for the Optional FBK-100 Kit

Factory Wired

Field Wired

Schematic Representation Only

Junction Box

Tab Intact

Tab

Broken

Plug blower

into this

receptacle

n

e

e

r

G

-

d

n

u

o

r

G

*Optional Accessory Switch

Optional

Blower

Ground

e

ti

h

W

-

l

a

rt

u

e

N

120 VAC - Black

Green

Ground

Screw

White

Green

Neutral

Side of

Receptacle

Hot

Side of

Receptacle

Red

Black

*J-BOX WIRING FOR

OPTIONAL (BLOWER

CONTROL) ACCESSORY

SWITCH

u

CAUTION: Label all wires prior to disconnec-

tion when servicing controls. Wiring errors can

cause improper and dangerous operation.

ATTENTION: Au moment de l'entretien des

commandes, étiquetez tous les fils avant de

les débrancher. Des erreurs de cáblage peu-

vent entraîner un fonctionnement inadéquat

et dangereux.

Verify proper operation after servicing.

S'assurer que l'appareil fonctionne adé-

quatement une fois l'entretien terminé.

CAUTION

Ground supply lead must be con-

nected to the wire attached to the

green ground screw located on the

outlet box. See Figure 47. Failure to

do so will result in a potential safety

hazard. The appliance must be

electrically grounded in accordance

with local codes or, in the absence of

local codes, the National Electrical

Code, ANSI/NFPA 70-latest edition.

(In Canada, the current CSA C22-1

Canadian Electrical Code).