beautypg.com

Calculating charge times – Sears 200.71233 User Manual

Page 13

background image

12

Calculating charge times

• Marine, or deep-cycle batteries are usually rated in

Reserve Capacity (RC).

NR means that the charger setting is NOT RECOM-

MENDED.

Find your battery’s rating on the chart below and note
the charge time given for each charger setting. The
times given are for batteries with a 50-percent charge
prior to recharging. Add more time for severly dis-
charged batteries.

CHARGE RATE/CHARGING TIME - HOURS

6 - 12 AH

12 - 32 AH

40 - 60 RC

60 - 85 RC

85 -190 RC

80 RC

140 RC

160 RC

180 RC

BATTERY SIZE/RATING

SMALL
BATTERIES

CAR/TRUCKS

MARINE/DEEP CYCLE

200 - 315 CCA

315 - 550 CCA

550 - 1000 CCA

Motorcycle, garden
tractor, etc.

The Hydrometer or Electronic Method

To find the time needed to fully charge your battery,
determine the battery’s charge level with a hydrometer
or electronic Percent-of-Charge Tester. The following
table will help you convert hydrometer readings to
percent of charge values.

SPECIFIC

PERCENT

PERCENT OF

GRAVITY

OF CHARGE

CHARGE NEEDED

1.265

100%

0%

1.225

75%

25%

1.155

25%

75%

1.120

0%

100%

When you know the percent of charge and the Amp
Hour (AH) rating of your battery, you can calculate the
approximate time needed to bring your battery to a full
charge.

To convert Reserve Capacity to Amp Hours, divide
Reserve Capacity by 2, and add 16:

Amp Hours = Reserve Capacity + 16

2

NOTE: The Reserve Capacity can be obtained from
the battery specification sheet or the owner’s manual.

To calculate time needed for a charge:

• Find the percent of charge needed. (A battery at 50

percent charge that will be charged to 100 percent
needs another 50 percent (.50).

• Multiply the Amp Hour rating by the charge needed

(.50) and divide by the charger setting
(2/15/50 amps).

• Multiply the result by 1.25 and you’ll have the time

needed, in hours, to bring the battery to full charge.

• Add one additional hour for a deep-cycle battery.

Example:

Amp Hour Rating x % of charge needed x 1.25 = hours

Charger Setting

of

charge

100 (AH Rating) x .50 (charge needed) x 1.25 = 4.16666

15 (Charger Setting)

hours

100 x .50 = 3.3333 x 1.25 = 4.16666
15

You would need to charge your 100-Ampere Hour
Battery for a little more than 4 hours at the 15-Amp
charge rate using the above example.

The Chart Method

Use the following table to more accurately determine
the time it will take to bring a battery to full charge.
First, identify where your battery fits into the chart.

• Small batteries — motorcycles, garden tractors, etc.

— are usually rated in Ampere Hours (AH). For
example: 6 to 12 AH, or 12 to 32 AH.

• Batteries in cars and smaller trucks are usually rated

in Reserve Capacity (RC), Cold-Cranking Amps
(CCA), or both.

50 AMP

NR

NR

30 - 40 min.

40 - 45 min.

45 - 90 min.

NR

NR

NR

NR

15 AMP

NR

NR

90 - 120 min.

120 - 130 min.

2.5 - 4.5

130 min.

3.5

4.0

4.5

2 AMP

2 - 4

4 - 10

11 - 14

14 - 18

18 - 35

18

27

30

33