Technical data – Sterling SDF 250 User Manual
Page 64

SDF 250/400/500
Technical data 9-1
9. Technical data
Basic Version
Central control unit for operating the dryer and the drying hoppers.
Drying temperature adjustment for all connected hoppers
•
SPS-S7 PLC
•
Touch-screen
•
Timer clock
•
Regeneration heater with safety temperature limiter
•
Isolated alarm output
•
Optical alarm
Optional Equipment
•
Adjustable, dew point dependent regeneration switch with dew point display
-Optimum efficiency due to continuos online dew point measurements
-Maximum drying quality - minimal energy consumption
-Significant energy savings when processing materials with a low initial moisture content
•
Controlled blowers
-Dry air volume optimally adapted to respective requirements
-No loss of heat during part-load operation
-Significant energy savings
•
Automatic air distribution through air distribution valves with fuzzy logic control
-Prevents the material from being exposed to un nec es sary ther mal stress
-Significant energy saving due to heater shut-off function
-Optimum operating safety due to special sensor technology
•
Throughput control at the drying hopper for automatic dwell time monitoring (only available
when used in conjunction with Sterling Central Conveyor System)
-Optimum protection for changing service conditions
-Alarm or removal stop if dwell time has not been reached
-Optimum operating safety through dwell time monitoring
•
Communication Interface
Performance
•
Maximum air drying capacity of 250 m3/hr up to 500 m3/h (depending on version)
•
Operates with 400 V +/-10 %, 3 AC, 50 Hz voltage
•
Average dewpoint temperature of -50° C (- 60 °F)
•
Compressed-air consumption valve stem: 3 l/h