SDF 250/400/500

Error and error correction 4-3

4.1. Actual messages

Following alarm messages can be displayed:

PLC (= SPS) Battery is Empty

Replace the SPS battery.

The Safety Switch Regeneration Blower Has Been Actuated

Check the blower.

Check the fuses.

Short circuit check of the blower.

Vacuum Regeneration Blower

The regeneration blower does not produce sufficient pressure.

Check the blower.

Vacuum sensor defective.

The Safety Switch Drying Blower Has Been Actuated

Check the blower.

Check the fuses.

Short circuit check of the blower.

Vacuum Drying Blower

The drying blower does not produce sufficient pressure.

Check the blower.

Vacuum sensor defective.

Temperature Measurement Regeneration Heater Defective

Check the cables and the sensor.

Check the power supply.

Short circuit check.

Excess Temperature Regeneration Heater

The regeneration temperature is too high.

Check the safety temperature limiter.

Sterling Service.

Insufficient Temperature Regeneration Heater

The regeneration temperature is too low.

Check the regeneration heater.