Troubleshooting – Sub-Zero 315 User Manual
Page 20

20
TROUBLESHOOTING
Problem
Possible Cause
Probable Correction
The ice maker does not operate
The ice maker is unplugged
Plug the ice maker in
Breaker tripped or fuse is blown
Reset breaker/replace fuse – if it happens again,
call for service to check for a short circuit in the
ice maker
Ice maker control turned to OFF
Turn ice maker control to ON
Bin thermostat open, keeping
Ice on sensor tube – its then
ice maker off
normal for the ice maker to be off
Ice maker in a room below 50˚F – room needs
to be warmer for ice maker to operate.
Bin thermostat stuck open, needs to be replaced.
Timer contacts open
Replace timer
Cubes are too big
Cube size control set too cold
Adjust cube size control for a smaller cube
Cubes are too small
Cube size control set too warm
Adjust cube size control for a larger cube
Not enough water
Check water supply – filter may be restricted
Check inlet water valve – inlet screen may be
restricted
Cube size control stuck closed –
Replace timer
timer runs all the time.
Cubes are partially formed –
Spray jets partially clogged
Clean ice making system with ice maker
have ragged sides
cleaner.
Ice maker makes ice, but bin
The bin should fill up and the
Clean the condenser.
does not fill up with ice
ice maker shut off in 24-36 hours.
If not, the condenser may be dirty
The bin drain may be partially
Clean out the drain, check the installation.
restricted
The air flow to the ice maker
Check the installation – the ice maker must be
may be obstructed
free of obstructions at the kickplate.
Cubes are partially formed –
Not enough water in the reservoir.
Check water supply – filter may be restricted
are white at the bottom
Check inlet water valve - inlet screen may be
restricted.
Check for a water leak at the reservoir.