beautypg.com

Sharp FO-475TH User Manual

Page 22

background image

UX-258TH
FO-475TH

SW-A6 No. 2 End buzzer

Setting this bit to 0 will disable the end buzzer (including the error buzzer/
on-hook buzzer).

SW-A6 No. 3 Disconnect the line when DIS is received in RX mode

Bit1= 0: When DIS signal is received during RX mode, disconnected the
line is immediately.

Bit1= 1: When DIS signal is received during RX mode, wait the next
signal.

SW-A6 No. 4 Equalizer freeze control (MODEM)

This switch is used to perform reception operation by fixing the equal-
izer control of modem for the line which is always in unfavorable state
and picture cannot be received.
*

Usually, the control is executed according to the state of line where

the equalizer setting is changed always.

SW-A6 No. 5 Equalizer freeze control 7200BPS only

Setting which specifies SW-A3 No. 6 control only in the condition of
7200BPS modem speed.

SW-A6 No. 6 CNG transmission in manual TX mode

When set to "1", fax transmit the CNG signal in case of manual trans-
mission mode (User press the START key after waiting the fax answer-
ing signal from handset or speaker).

SW-A6 No. 7 Initial compression scheme for sharp fax in TX mode

When set to "0", if the other fax is Sharp model, fax transmit the docu-
ment by H2 mode. When set to "1", even if the other fax is Sharp model,
fax transmit the document by MR mode.

SW-A6 No. 8 Reserved

Set to "0".

SW-B1 No. 1 ~ No. 4 Recall interval

Choice is made for a redial interval for speed and rapid dial calls.
Used a binary number to program this. If set to 0 accidentally, 1 will be
assumed.

SW-B1 No. 5 ~ No. 8 Recall times

Choice is made as to how many redials should be.

SW-B2 No. 1 Dialing pause (sec/pause)

Pauses can be inserted between telephone numbers of direct dial con-
nection. Selection of 4 sec or 2 sec pause is available.

SW-B2 No. 2, No. 3 Reserved

Set to "0".

SW-B2 No. 4 Busy tone detection (after auto dial)

Used to set YES/NO of busy tone detection after auto dialing.

SW-B2 No. 5 Waiting time after dialing

This is waiting time for the opponent’s signals after dialing.

When set to "0", waiting time is 45 sec.

When set to "1", waiting time is 90 sec.

SW-B2 No. 6 ~ No. 8 Reserved

Set to "0".

SW-B3 No. 1 ~ No. 7 Reserved

Set to "0".

SW-B3 No. 8 Hold function

Used to set YES/NO of holding function by the HOLD key.

SW-B4 No. 1 Auto dial mode Delay timer of before line connect

Delay time between the dial key input and line connection under the
auto dial mode.

SW-B4 No. 2 Auto dial mode Delay timer of after line connect

Delay time between the line connection and dial data output under the
auto dial mode.

SW-B4 No. 3 Dial mode

When using the pulse dial, set to 0. When using the tone dial, set to 1.
SW-B4 No. 4 Pulse

Tone change function by

key

When setting to 1, the mode is changed by pressing the

key from the

pulse dial mode to the tone dial mode.

SW-B4 No. 5 Dial pulse make/break ratio (%)

When using the 33 % make ratio pulse dial, set to "0".
When using the 40 % make ratio pulse dial, set to "1".

SW-B4 No. 6 ~ No. 8 Reserved

Set to "0".

SW-B5 No. 1 ~ No. 5 DTMF signal transmission level (Low)

The transmission level of DTMF signal is adjusted. (lower frequency)

00000: 0dBm

11111: -15.5dBm (-0.5dBm x 31)

SW-B5 No. 6 ~ No. 8 Reserved

Set to "0".

SW-B6 No. 1 ~ No. 5 DTMF signal transmission level (High)

The transmission level of DTMF signal is adjusted. (higher frequency)

00000: 0dBm

11111: -15.5 dBm (-0.5dBm x 31)

SW-B6 No. 6 ~ No. 8 Reserved

Set to "0".

SW-C1 No. 1, No. 2 Reading slice (Binary)

Used to determine the set value of reading density in standard/fine mode.
The standard setting is "00" (Factory setting is "00")

SW-C1 No. 3, No. 4 Reading slice (Half tone)

Used to determine the set value of reading density in half tone mode.
The standard setting is "00" (Factory setting is "00")

SW-C1 No. 5 Line density selection

Used to set the transmission mode which is automatically selected when
the Resolution key is not pressed. In the copy mode, however, the fine
mode is automatically selected unless the Resolution key is manually
set to another mode.

SW-C1 No. 6 Reserved

Set to "0".

SW-C1 No. 7 MTF correction in half tone mode

This allows selection of MTF correction (dimness correction) in the half
tone mode.
When "NO" (=1) is selected, the whole image becomes soft and mild.
On the contrary, however, clearness of characters will be reduced. Nor-
mally set to "YES" (=0).

SW-C1 No. 8 Reserved

Set to "0".

2 – 13

RAPID01

CML RELAY ON

DIALLING

0 : 0sec
1 : 3sec

RAPID01

CML RELAY ON

0 : 3 sec
1 : 3.6 sec

DIAL DATA