beautypg.com

Chapter 2. adjustments, 1] adjustments, General – Sharp FO-475TH User Manual

Page 10: Output voltage settings, Settings (1) dial mode selector, Ic protectors replacement, 2) contents

background image

UX-258TH
FO-475TH

CHAPTER 2. ADJUSTMENTS

[1] Adjustments

General

Since the following adjustments and settings are provided for this model,
make adjustments and/or setup as necessary.

1. Adjustments

Adjustments of output voltage (FACTORY ONLY)

1. Install the power supply unit in the machine.

2. Set the recording paper and document.

3. When the document is loaded, power is supplied to the output lines.

Confirm that outputs are within the limits below.

Output voltage settings

(1) FU100 (ICP-S07) is installed in order to protect IC’s from an over-

current generated in the motor drive circuit. If FU100 is open, replace
it with a new one.

3. Settings

(1) Dial mode selector

DIAL mode (Soft Switch No. SWB4 DATA No. 3)

Output

Voltage limits

+5V

4.75V

5.25V

+24V

23.3V

24.7V

2. IC protectors replacement

ICPs (IC Protectors) are installed to protect the motor driver circuit.
ICPs protect various ICs and electronic circuits from an overcurrent con-
dition.

The location of ICPs are shown below:

1

DG

2

+5V

3

VTH-ON

4

MG

5

MG

6

MG

7

+24V

8

VTH

9

VTH

10

VTH

Connector

No.

CNPW

Pin No.

2 – 1

TEL/LIU PWB

POWER SUPPLY PWB

CNLIU

CNLIUA

CN2

CNPW

CONTROL PWB

CONTROL PWB
(TOP SIDE)

CNLIUA

CNPW

FU100

4. Method of release of starting lock up by Battery

Reset

(1) Summary

There is a possibility of release of the lock up by reset the signal BATRST
of CPU (FC100), if it lock up when you turn on the power of the set in
UX-258 series. We inform you of the method of release.

(2) Contents

When you turn on the power of the set without EPROM by your mistake,
if you turn off the power after, turn on the power with EPROM again, the
set don’t start.

In this case, before you judge the cpu (FC100) is wrong, you need to
confirm the release of the lock up by reset the signal BATRST. and
unknown origin in the same way.

Method of the reset of signal BATRST
Short the between leads of the capacitor C5 on the control PWB,
X2961-81 in the state of POWER OFF.

(step 1) Select "OPTION SETTING".

KEY : FUNCTION 4

DISPLAY: OPTION SETTING PRESS OR #

(step 2) Select "DIAL MODE".

KEY:

DISPLAY: DIAL MODE 1=TONE, 2=PULSE

(step 3) Select, using "1" or "2".

KEY: 1

DISPLAY: TONE SELECTED

KEY: 2

DISPLAY: PULSE SELECTED

(step 4) End, using the "STOP" key.

KEY:

Cursor
When initially registering,
the mode shows 1=TONE.
When registering again, the
mode which was registered
formerly is shown.

STOP

#

#

#

#

#

#

#

#

#

This manual is related to the following products: