Temperature and Humidity Ranges
The following table indicates the temperature and humidity ranges
within which the air conditioner can be used.
If the air conditioner is used at...
Then...
High temperatures
The automatic protection feature may
be triggered and the air conditioner
stopped.
Low temperatures
A water leakage or some other
malfunction may happen if the heat
exchanger freezes.
High humidity levels
Water may condense on and drip
from the surface of the indoor unit if it
is used for long periods.
Mode
Outdoor Temperature
Indoor Temperature
Indoor Humidity
Cooling
70°F to 109°F approx.
65°F to 90°F approx.
21°C to 43°C approx.
18°C to 32°C approx.
80% or less
Drying
65°F to 109°F approx.
65°F to 90°F approx.
18°C to 43°C approx.
18°C to 32°C approx.
-
❇ If the cooling operation is used at over 92°F/33°C(indoor temperature)
then, does not a full capacity.
E-