beautypg.com

Installation 4 – Simer Pumps SIMER 3985 User Manual

Page 4

background image

For parts or assistance, call Simer Customer Service at

1-800-468-7867

5A. Power Supply: This pump requires a 115 V.,

60 Hz., 15 amp individual branch circuit. The cir-
cuit must be grounded and should be dedicated
to the sump pump.

5B. The pump is supplied with a 3-wire cord set with

grounding-type plug. Plug the switch directly into
the outlet and plug the pump into the opposite
end of the switch’s plug.

Electrical shock hazard. Always

ground the pump to a suitable electrical ground,
such as a grounded water pipe, a properly ground-
ed metallic raceway, or a ground wire system. Do
not cut off the round ground pin.

6A. After you have installed the piping, check valve,

and float switch, the pump is ready for operation.

6B. Check the pump by filling the sump with water

and observing the pump’s operation through one
complete cycle. For switch settings see the
Electrical and Switch Specifications chart on
Page 5.

Failure to make this operational

check may lead to improper operation, premature
failure, and flooding.

Installation

4

Figure 5

Figure 6

This manual is related to the following products: