beautypg.com

Mdf-c2156van, Mdf-c8v, Upright freezers – Sanyo MDF-C2156VAN User Manual

Page 5: Chest freezer, For cryogenic preservation, Perfect size for personal use

background image

2” box rack

Number of 2” boxes

3” box rack

Number of 3” boxes

MDF-U32V

IR-A216U(6) + IR-220U(6)

264

IR-312UN

144

MDF-U53V

IR-220U(8) + IR-224U(8)

352

IR-312U + IR-316U

224

MDF-U73V

IR-220U(12) + IR-224U(12)

528

IR-312U + IR-316U

336

MDF-C2156VAN

IR-210C(14)

140

IR-307C(14)

98

MDF-C8V

IR-207C(6)

42

Upright freezers

MDF-U32V/U53V/U73V

Offers maximum storage volume in the
least footprint

Set value

Current value

Message

Date/time

Door display

Status display

Warning information display

Full suite of sample protection measures

Advanced design, construction and control features provide added
safety for valuable specimens.

• New double type lid gasket ensures an effective seal and suppresses

cold air loss.

• New VIP PLUS insulation material improves the insulation perfor

mance of the cabinet.

• Equipped with new Status alert function.

• Equipped with LN

2

backup system as standard to prepare for any

contingency.

Simplified high-efficiency
refrigerating system

• Use of a newly developed single-com-

pressor system achieves an approxi-
mately 40% reduction in power con-
sumption.

• Low-noise design provides quiet, unob-

trusive operation ideal for in-lab use.

New cooling circuit enables filter-less design

Filter-less design makes the routine maintenance procedure of
cleaning the condenser filter unnecessary.

Inner door

Control panel

The control panel features a clear LED display and a logical keypad
layout for easy setting and operation.

Provides large capacity in a
limited space and helps to
meet constantly increasing
sample storage needs.

Space-saving design enables effective
use of valuable laboratory space.

Innovative control panel

A graphic LCD display panel with pop-up menu function allows simple,
intuitive operation and provides detailed information of freezer status.

Chest freezer

MDF-C2156VAN

for cryogenic preservation

MDF-U53V

Data logging function

Internal temperature and
times when the outer lid has
been opened for more than
2 minutes can be recorded for up to 1 month. Logged data can also
be easily sent to a PC using the optional communication interface.

Cabinet Construction

Insulated inner doors with gasket
offer additional protection during door
opening and improve overall energy
efficiency in response to ambient
temperature change.

Easily removable inner doors

Inner doors are removable to allow
easy cleaning and defrosting.

Chest freezer

MDF-C8V

Perfect size for personal use

Using ultra-low tempera-
ture freezer storage for
long-term preservation of
valuable specimens elim-
inates worries of contam-
ination, reduces running
costs, and enables long-
term storage at ultra-low
temperatures far below
the recrystallization point.

Easy-to-use tight-sealing door latches

• The rugged, one-handed operated outer door

latch can accommodate a padlock for added
protection of valuable samples.

• A beak style inner door latch tightly closes

the inner door against the freezer frame. It
also helps make opening and closing the
door smoother.

High-density storage

Large door latch

Inner door latch

This manual is related to the following products: