SECO-LARM USA Enforcer RF Receivers SK-910R-4 User Manual
Page 4

SECO-LARM
®
U.S.A., INC.
16842 Millikan Avenue
Irvine, CA 92606
Telephone
(800) 662-0800
(949) 261-2999
The SECO-LARM policy is one of continual development and improvement.
For this reason, SECO-LARM reserves the right to change specifications without further notice.
FILE: TE-10, C:\DTP\MANUAL\MUK910R2.P65 APR2001
ORDER PART# 762-091-4 (904)
General Specifications
Operating Frequency:
315 MHz (SK-910R, SK-910RL, SK-910R2)
433.92 MHz (SK-910R-4, SK-910RL-4, SK-910R2-4)
Memory Capacity:
15 transmitter button codes per channel
Operating Voltage:
11VDC ~ 24VDC or 11VAC ~ 24VAC
5VDC ~ 13VDC (SK-910RL / SK-910RL-4 only)
Operating Current:
8 mA @ 12VDC (standby)
30mA/channel @ 12VDC (activated)
70mA @ 6VDC (activated), (SK-910RL / SK-910RL-4 only)
Relay Contact Rating:
Form ‘C’ type; 10A @ 24VDC or 120VAC per channel
Connectors:
Screw Terminals, +, –,
with N/O, N/C, and COM per channel
Dimensions:
3.25” x 2.7” x 1.1” (83 x 68 x 27.5 mm)
Compatible Transmitters
COM
NC
NO
-
+
COM
NC
NO
-
+
COM
NC
NO
-
+
COM
NC
NO
-
+
Positive Power Source
Positive Power Output
Power for SK-910R
Negative Power Source
Negative Power Output
Power for SK-910R
12VDC O/P
GND
+12VDC
24VAC(1) Input
24VAC(1) Output
GND
+12VDC
}
}
315 MHz
SK-919TD1S
1-button, Fixed Code
SK-919TD2A
2-button, Fixed Code
SK-917T3A
3-button, Code Hopping
SK-917T2A
2-button, Code Hopping
433.92MHz
SK-939TS1S
1-button, Fixed Code
SK-939TS2A
2-button, Fixed Code
SK-937TS2A
2-button, Code Hopping
SK-937TS3A
3-button, Code Hopping
Typical Applications:
Positive Output:
Negative Output:
12VDC receiver power driving a 12VDC apliance:
12VDC receiver power input, 24VAC output driving a motor
}
Power for SK-910R
24VAC(2)
Motor
2
1
Fax
(949) 261-7326