beautypg.com

Sanyo EM-842WS User Manual

Page 14

background image

NOTE

NOTE

NOTE

NOTE

NOTE : If the Interlock Monitor Circuit operates and at the

same time the fuse blows with the Door opened,
be sure to replace the Control Circuit Board because
Relay 2 on the Control Circuit Board, the Door
Sensing Switch and the electric circuit related
on the Door Sensing Switch, which act as
Secondary Interlock Switch.

Test Procedures and Troubleshooting ....................

4 ~ 10

Disassembly Instructions .......................................

11 ~ 14

Exploded View and Parts List ................................

15 ~ 20

Overall Circuit Diagram ..........................................

21

Adjustment Procedures ...................................................

1

Specifications ..................................................................

2

Power Output Measurement ...........................................

2

Precautions and Repair Service Tips ..............................

2

Circuit Diagram ...............................................................

3

1 .

1 .

1 .

1 .

1 . ADJUSTMENT PROCEDURES

ADJUSTMENT PROCEDURES

ADJUSTMENT PROCEDURES

ADJUSTMENT PROCEDURES

ADJUSTMENT PROCEDURES

TTTTTO A

O A

O A

O A

O AVOID POSSIBLE EXPOSURE TO MICROW

VOID POSSIBLE EXPOSURE TO MICROW

VOID POSSIBLE EXPOSURE TO MICROW

VOID POSSIBLE EXPOSURE TO MICROW

VOID POSSIBLE EXPOSURE TO MICROWA

A

A

A

AVE

VE

VE

VE

VE

ENERGY LEAKAGE, THE FOLLOWING

ENERGY LEAKAGE, THE FOLLOWING

ENERGY LEAKAGE, THE FOLLOWING

ENERGY LEAKAGE, THE FOLLOWING

ENERGY LEAKAGE, THE FOLLOWING
ADJUSTMENT OF THE INTERLOCK SWITCHES

ADJUSTMENT OF THE INTERLOCK SWITCHES

ADJUSTMENT OF THE INTERLOCK SWITCHES

ADJUSTMENT OF THE INTERLOCK SWITCHES

ADJUSTMENT OF THE INTERLOCK SWITCHES
SHOULD BE MADE ONL

SHOULD BE MADE ONL

SHOULD BE MADE ONL

SHOULD BE MADE ONL

SHOULD BE MADE ONLY BY AUTHORIZED

Y BY AUTHORIZED

Y BY AUTHORIZED

Y BY AUTHORIZED

Y BY AUTHORIZED

SER

SER

SER

SER

SERVICE PERSONNEL.

VICE PERSONNEL.

VICE PERSONNEL.

VICE PERSONNEL.

VICE PERSONNEL.

The SANYO service center should have the designated
detector to measure the microwave energy leakage
after the repair or adjustment.

NOTE

NOTE

NOTE

NOTE

NOTE : Detector to be used at the service center is

NARDA 8100, 8200 or the equivalent.

PRIMAR

PRIMAR

PRIMAR

PRIMAR

PRIMARY INTERLOCK SWITCH, INTERLOCK

Y INTERLOCK SWITCH, INTERLOCK

Y INTERLOCK SWITCH, INTERLOCK

Y INTERLOCK SWITCH, INTERLOCK

Y INTERLOCK SWITCH, INTERLOCK

MONITOR SWITCH AND DOOR SENSING SWITCH

MONITOR SWITCH AND DOOR SENSING SWITCH

MONITOR SWITCH AND DOOR SENSING SWITCH

MONITOR SWITCH AND DOOR SENSING SWITCH

MONITOR SWITCH AND DOOR SENSING SWITCH
ADJUSTMENT

ADJUSTMENT

ADJUSTMENT

ADJUSTMENT

ADJUSTMENT

(Figure 1)

(Figure 1)

(Figure 1)

(Figure 1)

(Figure 1)

(1)

Loosen 2 screws securing the Lever Stopper.

(2)

Adjust the Lever Stopper position so that it is pushed
forward and pull backward until there is about zero
gap between the Latch Lever and the switch body on
the Primary Interlock Switch and at the same time
there is about zero gap between the Door Latch and
the switch body on the Door Sensing Switch when
the Door Latch is securely locked.

(3)

Tighten the Lever Stopper screws securely.

(4)

Make sure the Interlock Monitor Switch closes after
the Primary Interlock Switch opens when the Door
is opened very slowly, according to “CHECKOUT
PROCEDURE FOR SWITCHES” on page 6.

(5)

Make sure the Interlock Monitor Switch opens before
the Primary Interlock Switch closes when the Door is
closed very slowly, according to “CHECKOUT
PROCEDURE FOR SWITCHES” on page 6.

(6) Make sure the microwave energy leakage should be

no greater than 4mW/cm

2

to allow for measurement

uncertainty when measured with a detector.

(All service adjustments must be made for
minimum microwave energy leakage readings.)

- TABLE OF CONTENTS -

Lever Stopper

Door
Sensing
Switch

Door
Latch

Interlock
Monitor
Switch

Primary
Interlock
Switch

Screws

Latch
Lever

Figure 1

Figure 1

Figure 1

Figure 1

Figure 1

- 1 -