beautypg.com

Htma requirements – Stanley Black & Decker HD45 User Manual

Page 9

background image

9

HTMA REQUIREMENTS

FLOW RATE

TOOL OPERATING PRESSURE
(at the power supply outlet)

SYSTEM RELIEF VALVE SETTING
(at the power supply outlet)

MAXIMUM BACK PRESSURE
(at tool end of the return hose)

Measured at a max. fl uid viscosity of:
(at min. operating temperature)

TEMPERATURE
Suffi cient heat rejection capacity
to limit max. fl uid temperature to:
(at max. expected ambient temperature)

Min. cooling capacity
at a temperature difference of
between ambient and fl uid temps

NOTE:
Do not operate the tool at oil temperatures above 140° F (60° C). Operation at higher temperatures can cause operator
discomfort at the tool.

FILTER
Min. full-fl ow fi ltration
Sized for fl ow of at least:
(For cold temp. startup and max. dirt-holding capacity)

HYDRAULIC FLUID
Petroleum based
(premium grade, anti-wear, non-conductive)
VISCOSITY
(at min. and max. operating temps)

NOTE:
When choosing hydraulic fl uid, the expected oil temperature extremes that will be experienced in service determine the
most suitable temperature viscosity characteristics. Hydraulic fl uids with a viscosity index over 140 will meet the require-
ments over a wide range of operating temperatures.

*SSU = Saybolt Seconds Universal

4-6 gpm

7-9 gpm

11-13 gpm

9-10.5 gpm

(15-23 lpm)

(26-34 lpm)

(42-49 lpm)

(34-40 lpm)

2000 psi

2000 psi

2000 psi

2000 psi

(138

bar) (138

bar) (138

bar) (138

bar)


2100-2250 psi 2100-2250 psi 2100-2250 psi 2200-2300 psi
(145-155 bar) (145-155 bar) (145-155 bar) (152-159 bar)

250

psi 250

psi 250

psi 250

psi

(17 bar)

(17 bar)

(17 bar)

(17 bar)

400 ssu*

400 ssu*

400 ssu*

400 ssu*

(82 centistokes) (82 centistokes) (82 centistokes) (82 centistokes)

140° F

140° F

140° F

140° F

(60° C)

(60° C)

(60° C)

(60° C)

3 hp

5 hp

7 hp

6 hp

(2.24 kW)

(3.73 kW)

(4.47 kW)

(5.22 kW)

40° F

40° F

40° F

40° F

(22° C)

(22° C)

(22° C)

(22° C)

25 microns

25 microns

25 microns

25 microns

30

gpm 30

gpm 30

gpm 30

gpm

(114 lpm)

(114 lpm)

(114 lpm)

(114 lpm)

100-400 ssu*

100-400 ssu*

100-400 ssu*

100-400 ssu*

(20-82 centistokes)

TOOL CATEGORY

HYDRAULIC SYSTEM
REQUIREMENTS TYPE 1 TYPE II TYPE III TYPE RR

NOTE:

These are general hydraulic system requirements. See tool Specifi cation page for tool specifi c requirements.