Electrical requirements, Water requirements, Drain requirements – Southbend STRE-5EZ User Manual
Page 6

O
PERATION
S
TRATO
S
TEAM
EZ
C
OUNTERTOP
S
TEAMER
P
AGE
6
OF
56 O
WNER
’
S
M
ANUAL
1189953
(10/08)
E
LECTRICAL
R
EQUIREMENTS
One fused electrical connection is required to the contactor of each steamer. All steamers are shipped per customer
order, three phase or single phase. (A kit is available for field conversion to three phase or single phase.) The fused
connection must be wired for the required voltage and maximum amperage as listed in the chart below:
Total Connected Amps
Model STRE-3EZ
Model STRE-5EZ
Voltage
1 Phase
3 Phase
1 Phase
3 Phase
208 V 60 Hz
44
26
53
31
220 V 50/60 Hz
41
24
51
29
240 V 60 Hz
38
22
46
27
W
ATER
R
EQUIREMENTS
To meet warranty requirements, the water supply must be as follows:
Total Dissolved Solids (TDS)
60 PPM or less
Hardness
2 grains (35 PPM) or less
pH
7.0 to 7.5
Chlorine and/or bromine
1 PPM or less
Maximum Reservoir Capacity
3.0 gallons
Typical usage is 3.0 gallons in 4 hours.
In order to minimize service problems and to meet the warranty requirements, a water treatment system (softener) is
recommended when water quality does not meet the limits stated above.
D
RAIN
R
EQUIREMENTS
Water drains into a pan attached to the bottom of the steamer. Pan pulls out for periodic dumping.