beautypg.com

Schumacher SE-70MA User Manual

Page 12

background image

8

Charge Rate Selector Switch (Voltage/Amp Selector)

Use this switch to set the maximum charge rate to one of the following.

2A Slow Charge Rate

– Intended for charging small batteries such as those

commonly used in garden tractors, snow mobiles and motorcycles. The 2A

rate can be used to warm or trickle charge larger batteries.
6A, 10A, 12A, 15A Fast and 30A Rapid Charge Rate

– Use for charging

automotive, marine and deep-cycle batteries. Not intended for industrial

applications.
Engine Start

– Provides additional amps for cranking an engine with a weak

or run down battery. Always use in combination with a battery.

Voltage Selector Switch

Use this switch to set the charger to charge a 6 volt, 12 volt or 24 volt battery.
NOTE: These chargers are not recommended for 8 or 16 volt systems.
LED Indicators

Full Charge

– When lit, this LED indicates that the battery is fully charged

and the charger has stopped charging and switched to the Maintain Mode of

operation (Automatic chargers only).
Power On

– When lit, this LED indicates that there is AC power supplied to

the battery charger.
Check Battery

– When lit, this LED indicates there is something wrong with

the battery. Check the DC connections for an improper connection; otherwise

the battery may be bad.

OPERATING INSTRUCTIONS

11.

Overview

Connect the battery following the precautions listed in Sections 6 and 7.

1.

Select the appropriate settings for your battery.

2.

Connect the AC power following the precautions listed in Section 8.

3.

Automatic Charging

If the charger has an Automatic Charge Mode, it can perform an automatic

charge. When an Automatic Charge is performed, the charger switches to the

Maintain Mode (see below) automatically after the battery is charged. For a

battery with a starting voltage under 1 volt, use the Manual Mode first to pre-

charge the battery for five minutes to get additional voltage into the battery for

the charger to analyze.
Manual Charging

If the charger does not have an Automatic Charge Mode, you will be charging

in Manual Mode. A manual charger will continue to charge and will not shut off.

You must keep a visual check on the ammeter to determine when the battery is

charged. Be sure to monitor the charging process and stop it when the battery

is charged. Not doing so may cause damage to your battery or result in other

property damage or personal injury.
Completion of Charge (Automatic Chargers Only)

When the FULL CHARGE (green) LED is lit, the charger has stopped charging

and switched to the Maintain Mode of operation. If the 12V DEEP CYCLE

battery type was selected, the CHARGED (green) LED comes on when the

battery is charged enough for normal use.