PROBLEM

Does not turn on
or machine shuts off
intermittently

Bag full or clog light on
or flashing &
machine shuts off

Brush light on

Brush light slowly
flashing

Brush light flashing &
machine shuts off

Up & down lights flicker

Does not pick up

Front bag door won’t
fully close

Hose doesn’t retract
after attachment tube is
inserted

REASON

1. Handle not fully inserted into the bag

housing, causing a faulty connection.

2. Not plugged into good outlet.

3. Cable worn.

4. Dust bag housing (6) not seated

fully into proper “locked” position
on top of power head.

1. Bag full.

2. Clog in airflow pathway, attach-

ment hose, attachment tube, swivel
neck or entrance to dust bag.

3. Microfilter dirty.

1. Brush worn.

1. Vacuum is stationary and in

upright locked position.

1. Brush jammed.

1. Operating on uneven floor.

1. Attachment tube not

correctly inserted.

2. Front cover not closed.

1. Cover release flap not fully closed.

2. Bag not inserted properly

3. Microfilter not properly inserted.

1. Attachment tube not properly

inserted.

SOLUTION

1. Release handle catch, push handle

down, close handle catch.

2. Use another outlet.

3. Replace cable.

4. Housing release button (8) should

be snapped outward to its locked
position.

1. Replace bag. See #5 on page 4.

2. See Clog Removal on page 9.

Also, see #5 on page 4.

3. Replace microfilter.

1. See #3 on page 4.

1. See #4 on page 4.

1. See #2 on page 4.

1. Ignore.

1. Reinsert attachment tube, making

sure lower end of tube is in the
lower hole and handle is properly
seated over the projection tab (22).

2. See below.

1. Reinsert bag. Lock the cover

release flap down firmly.

2. Reinsert bag with cover release

flap (5) up, until firmly latched in
bag holder (see pg. 8, figure 7).

3. Lift safety lever and insert filter with

vertical plastic ridge on filter facing
you (see pg. 8, figure 8).

1. Reinsert making sure top of handle

is pointing back and tube is fully
seated on the protruding tab (22)
on top of the dust bag housing.

Trouble-Shooting Guide