Insteon keypadlinc v2 dimmer user’s guide – Smarthome NSTEON KEYPADLINK 2486D User Manual
Page 10

INSTEON KeypadLinc V2 Dimmer User’s Guide
Using KeypadLinc Dimmers in Virtual Multi-Way Circuits
In a virtual multi-way circuit, only one KeypadLinc Dimmer, called the KeypadLinc Primary, actually 
controls the LOAD in the multi-way circuit. Any additional KeypadLinc Dimmers, called KeypadLinc 
Secondaries, are not connected to the LOAD, but only to the powerline (via the LINE and NEUTRAL). All 
of the KeypadLinc Dimmers can communicate with one another using INSTEON networking on the 
powerline. After wiring in the KeypadLinc Dimmers, you create the virtual multi-way circuit by setting up 
all of the KeypadLinc Dimmers to control each other (see HOW TO SET UP KEYPADLINC DIMMER TO 
REMOTELY CONTROL AN INSTEON DEVICE, below). 
The diagram below shows how you convert a wired-in three-way circuit into a virtual three-way circuit 
using two KeypadLinc Dimmers. Step-by-step instructions for wiring in the KeypadLinc Dimmers are in 
the next section.
otice that one of the TRAVELER wires (number 1, the red one) is not used, so you will cap it off at both
(number 2, the black one) you will convert to a LINE wire. In the junction box
o the actual lights that are being controlled.
ted to
r Secondaries, must be connected to NEUTRAL
LINE
Black*
NEUTRAL
White*
GROUND
Bare Copper
LINE
Black
NEUTRAL 
White 
LOAD 
Red
Light
Fixture(s)
LOAD
Red* or Blue*
GROUND
Bare Copper
LINE
Black
NEUTRAL 
White 
GROUND
Bare Copper
LOAD 
Red
TRAVELER 1 
Red* or Blue* 
TRAVELER 2
Black*
KeypadLinc
Secondary
KeypadLinc
Primary
Main Panel
120 VAC
 
 
NOTE
 Wire colors 
marked with a * 
are the usual 
colors and may 
differ in some 
homes. 
N
ends with a wire nut. 
The other TRAVELER
where the KeypadLinc Secondary is, connect TRAVELER 2 to the existing LINE and also to the 
KeypadLinc Secondary’s LINE wire. In the other junction box at the other end, you will connect 
TRAVELER 2 to the KeypadLinc Primary’s LINE wire. 
The KeypadLinc Primary’s LOAD wire gets connected t
The LOAD wire for any KeypadLinc Secondaries that you will be installing will not be connec
anything, so cap those LOAD wires off with a wire nut. 
All KeypadLinc Dimmers, whether they are Primaries o
and to GROUND. Note that the switches you are replacing will not normally have a connection to 
NEUTRAL. If there is no NEUTRAL wire in the junction box, please consult an electrician or call 
SmartHome Tech Support, 800-SMARTHOME (800-762-7846). 