Start time 1, Start time 2 – ScyTek Electronics 5000RS User Manual
Page 39
Galaxy 5000/2000RS-DBP - Page 35
16. Auxiliary 3 Output Mode. Selects between Channel 3, Factory Rearm output, or third Ignition
ouput.
17. Lock After Start. When selected, the doors will automatically lock after remote starting.
Using button 3 disabled Mp Siren Mode.
18. Lock After Shutdown. When selected, the doors will automatically lock after remote shutdown.
19. Engine Run Time. Selects between 15 or 25 minutes for the remote start run cycle.
20. Automatic Start Mode. Selects between every two hours or every one hour for the automatic
engine starting feature.
Disable Start Time 1 & 2. Disables unit internal
Start Time 1
&
Start Time 2.
21 Tachless Sense Crank Time. Selecting engine crank time automatically selects the tachless mode
and one of three crank times.
If the normal engine crank time is too short increase the time by selecting one of the two additional
extended crank time options.
Normal -
0.8Sec.
Extended -
1.0Sec.
Super Extended - 1.4Sec.
Tachless Mode. Determines the engine status using an advanced software routine, without requiring
connection to the vehicle’s tachometer. Tachless operation may not be compatible with some vehicles
or in severe temperatures, in which case the tach wire must be connected.
22. Smart Start Temperature Compansation. adjusts crank time to compansate for temperature
variations.
23. Engine Sense Mode. Enable or disable smart sense monitor, or select DataBus RPM sense.
DataBus RPM sense - start the engine, enter Branch 23, Press Button 3 to learn the vehicle’s tach
signal. The siren will chirp three times to confirm that the tach signal was learned. If the
tach signal was not learned the siren will chirp once.
24. RPM Learn/Tach Monitor This dual program branch sets the engine mode for Gas or Diesel, and
learns the vehicle’s RPM threshold. For installation into a diesel equipped vehicle, first set the engine
type to diesel before learning RPM.
RPM Learn/Tach Monitor. start the engine, enter Branch 21, the LED light will flash continuasly to
indicate it is reading the tach signal. Press Button 1 to learn the vehicle’s tach signal. The siren will
chirp and the LED will flash once to confirm learning of the tach signal. The siren will chirp four
times and the LED will flash four times if the tach signal was not learned.
Tach Monitor mode: monitors the vehicle’s tach wire (or a fuel injection wire) in real-time to
determine engine status and adjust starter crank time automatically.
Gas Engine. Sets the engine type for Gasoline.
Diesel Engine. Sets the engine type for Diesel and monitors the glow plug input to make sure the
glow plugs are warm before cranking the starter. If the glow plug wire is not connected, the built-in
timer waits 15 seconds before automatically cranking the starter.
25. Ignition 2 Relay Program. Selects one of three operating modes for the Ignition 2 relay output:
Ignition 2, Accessory 2, or Starter 2.
26. Wait to Start Polarity input. Select positive or negative wait to start input.
27. External Sensor Mode. Select sensor-2 input as an additional sensor input, or an external start
trigger.