11

CONTROL PANEL

RETURN

PRESSURE

H.T.M.A. 1/2 INCH MALE

QUICK DISCONNECT

COUPLER

H.T.M.A. 1/2 INCH FE-

MALE QUICK DISCON-

NECT COUPLER

1/2 INCH I.D. HOSE, 25 FT
LONG WITH 2500 PSI/
172 BAR RATING AND
4 TO 1 SAFETY FACTOR

PRESSURE

RETURN

1/2 INCH MALE PIPE HOSE END

1/2 INCH MALE PIPE HOSE END

ADAPTER, 3/8 INCH MALE PIPE x

-8 SAE O-RING

H.T.M.A. 1/2 INCH MALE

QUICK DISCONNECT

COUPLER

H.T.M.A. 1/2 INCH FE-

MALE QUICK DISCON-

NECT COUPLER

TOOL

RETURN

Figure 2. Hydraulic Connections

DO NOT OVERTIGHTEN THE FITTINGS.

5. BATTERY

The supplied 12 Volt DC battery is a non-spillable, mainte-
nance-free battery and is fully charged.

Make sure the battery cables are tight and charging circuit
functions are operating properly.

OPERATION

Do not charge the battery with a standard auto-
motive battery charger. This type of charger pro-
duces a charging amperage higher than 2 amps.
Charging the battery at higher than 2 amps will
damage the battery.

NOTICE

NOTICE

If the engine runs out of gas or dies during op-
eration and the ignition switch is left in the ON or
RUN position, this could drain the battery. Make
sure the ignition switch is returned to the OFF
position.