beautypg.com

Notice, Mounting, Calibration – Woodstock D4028 User Manual

Page 2: Battery, Troubleshooting

background image

-2-

D4028/D4032 Digital Scale

Mounting

The digital scale can be mounted to machinery in various

ways. The goal is to attach either the display unit or scale

body to a fixed machine part and the other component

to the movable machine part. This allows you to measure

the relative distance the movable machine part travels.

IMPORTANT: Choose the digital scale model that has a

scale body longer than the full travel of the parts being

measured. This will ensure that the display unit is not

damaged as the machine parts move through their full

range of motion.

Calibration

When the digital scale is properly attached to the

machine, bring the movable machine part to the starting

position, then press the ON/Zero button to zero the

display. Position the movable machine part a known

distance from the starting point, then use the decreasing

and increasing buttons to make the display reading agree

with the known distance.

Battery

If the digital display does not come on or it flashes, the

battery voltage is low. Turn the unit OFF, remove the

battery compartment cover by sliding it to the right, then

replace the battery. Re-install the cover before turning

the unit ON.

Troubleshooting

Problem

Possible Cause

Corrective Action

Flashing digits.

Low battery.

Replace the battery.

Frozen digits.

Internal circuit error. Remove battery, wait

30 seconds, then

replace battery.

No display.

Low battery voltage;

poor contact.

Replace

battery;

make sure the bat-

tery contacts are

clean.

NOTICE

The Model D4028/D4032 digital scale is

not designed to be used around liquids

of any kind. Exposing the display unit to

liquids could cause permanent damage

to the internal electronics, which will

not be covered under warranty.

This manual is related to the following products: