Siemens HD2525U User Manual
Page 9
Safety Instructions
Preparation
Installation
Final Steps
English •
7
Safety Instructions
Preparation
Installation
Final Steps
Ser
vice
The gas connection is located below the back panel of
the range (See Figure 4, Page 4). It is accessible through
the warming drawer access panel or from the back of the
range. To reach access panel, remove warming drawer.
Shut off main gas supply valve before disconnecting the
old range and leave it off until the new hook-up has been
completed. Don’t forget to relight the pilot on other
gas appliances when you turn the gas back on.
The range can be installed using rigid pipe or a CSA
International-certified flexible metal appliance connector.
If using a flexible connector, always use a new connector.
Apply pipe joint compound orTeflon* tape appropriate for
use with LP gas and Natural gas around all male pipe
threads to prevent leaks.
If not already present, install gas shut off valve in an
easily accessible location. Make sure all users know
where and how to shut off the gas supply to the range.
Note: The installer should inform the consumer of
the location of the gas shut-off valve.
Step 7: Installation - Connect Gas Supply
Flexible Connector Method (see Figure 11,
this page)
1. Install male 1/2” flare adaptor at the 1/2” NPT internal
thread of the range inlet. Use a backup wrench on
the elbow fitting to avoid damage.
2. Install male 1/2” or 3/4” flare union adapter on the
NPT internal thread of the manual shut-off valve.
3. Connect flexible metal appliance connector.
4. Make sure circuit breaker is off and then plug range
cord in to electrical outlet.
5. Push range back into position insuring that range leg
slides under the anti-tip bracket. The range will sit
3/4” away from the wall when properly installed.
Note: Be careful not to crimp flexible connector!
6. Carefully tip range forward to insure that anti-tip
bracket engages and prevents tip-over.
Important note for LP users: The appliance is
shipped from the factory for use with natural gas. It
must be converted for use with propane. A qualified
technician or installer must do the conversion.
Figure 11: Flexible Connector Method
Gas Shut-Off
Valve
Flexible
Connector
Regulator
Proceed to “Test for Gas Leaks”, next column.
Test for Gas Leaks
Leak testing is to be conducted by the installer according
to the instructions given in this section.
Turn on Gas. Apply a non-corrosive leak detection fluid to
all joints and fittings in the gas connection between the
shut-off valve and the range. Include gas fittings and
joints in the range if connections were disturbed during
installation. Bubbles appearing around fittings and
connections indicate a leak.
If a leak appears, turn off supply line gas shut-off valve
and tighten connections. Retest for leaks by turning on
the supply line gas shut-off valve. When leak check is
complete (no bubbles appear), test is complete. Wipe off
all detection fluid residue. Proceed to Step 8: Test the
Installation.
gas shut off valve
elbow
nipple
nipple
nipple
union
elbow
1/2” to 3/4”
gas pipe
Gas Flow to Range
Figure 12: Rigid Pipe Method
elbow:
connect to
regulator here
Rigid Pipe Method (see Figure 12, this page)
The configuration of the rigid pipe connection will vary
depending on the location of the gas pipe stub. Refer to
Figure 12 for details.
1. Make sure circuit breaker is off and then plug range
cord in to electrical outlet.
2. Push range back into position insuring that range leg
slides under the anti-tip bracket. The range will sit
3/4” away from the wall when properly installed.
3. Carefully tip range forward to insure that anti-tip
bracket engages and prevents tip-over.
4. Connect pipe to range at union. Access the
connection through the access panel behind the
warming drawer.
Note: Be careful not to apply pressure to warming drawer
element during rigid pipe installation.
NEVER CHECK FOR LEAKS WITH A FLAME.
DO NOT CONTINUE TO THE NEXT STEP UNTIL ALL
LEAKS ARE ELIMINATED.
CAUTION
Before you plug in an electrical cord, be sure all
controls are in the OFF position.
CAUTION