Maintenance – Smeg WO-01 User Manual
Page 10

-
36
-
4. Maintenance
The osmosis treatment unit runs completely
automatically and maintenance is minimal. The
only essential operation is periodic replacement
of the filter cartridges.
IMPORTANT
Replace the pre-filter every 3000 hours of
operation and AT LEAST 1 time a year.
Pre-filter Membrane
Replacing the pre-filter:
Filter cartridge replacement procedure
-
Shut off power;
-
Close the side cocks (RL);
-
Vent the circuit from the top cap (S);
-
Unscrew the filter housing (use the special wrench supplied in the
accessories bag). Place a container to drain the water in the filter
into;
-
Fit the new cartridge and check it is correctly seated;
- Close
vent
S and open the side cocks RL;
-
Check for leaks and water in the bottom of the appliance;
-
Dry it off thoroughly.
Replacing the membranes:
Cartridge replacement procedure.
-
Shut off power;
- Disconnect all hoses from the membrane
housings, unscrew the base, and place a
container to catch the water contained in the
cartridges;
-
Refit the membrane, check the seating of the
o-ring and screw the housing fully in;
reconnect the hoses and make sure they are
correctly seated;
-
Do not apply excessive force;
-
Fit the new cartridge and check it is correctly
seated;
-
Start the unit up and check for leaks.