LOCATION OF UNIT

Locate pump as near as possible (vertically) to water
source, to keep suction lift (distance form water to pump)
as low as possible. Place pump on level support. Protect
against excess moisture and flooding.

PIPING

Both suction and discharge ports are tapped for 3/4"
pipe. If using hoses, use hose to pipe thread adapter. To
prevent suction line collapse, use pipe or reinforced hose
only for suction line. Install strainer or puddle gulper on
end of suction line. Inspect and clean strainer frequently
(Fig. 1). Plastic pipe can be used for all installations.

PRIMING/OPERATION

NOTICE: Do not run pump dry. Running pump without
water can damage impeller and may damage seal, caus-
ing leaking or flooding, and will void warranty.
All suction connections must be airtight. Make sure
suction lift is not more than 25' (7.6M). Fill pump body
through priming port before starting pump. Start pump;
it should pump water in under 10 minutes (depending
on length of suction hose and height of pump above
water).

ELECTRICAL

Risk of dangerous or fatal electric shock.
Unplug pump before servicing it. Do not
handle pump or attempt to work on pump

with wet hands or while standing on wet or damp floor.
Plug pump into 115 Volt, 60 Cycle outlet only. Pump is
equipped with 3-wire, grounded, cord and plug. Do not
modify or remove plug. Plug in to properly grounded,
grounding type outlet only. Make sure pump circuit
meets National Electrical Code. To avoid dangerous elec-
trical shock hazard, keep cord dry at all times.

Installation

4

For parts or assistance, call Simer Customer Service at

1-800-468-7867 / 1-800-546-7867

IN

OUT

Figure 2: Remove the priming plug and fill the pump
body with water.The pump must be full of water before
you start it!

IN

OUT

3/4" Discharge
Hose or Plastic
Pipe

NOTICE:
Pump suction port must
be 25' (7.6M) or less
above water level.
Max. water temp. is
104° F (40°C).

115 Volt grounded

outlet box.

Priming
Plug

Puddle Scoop
(Clean Frequently)

Operate pump on
115 volt curent only!

Electrical shock hazard. Pump and motor

are not submersible. Keep them dry!

3/4" Suction Hose

Figure 3:Typical Installation. Be sure to connect the
pump to a grounded outlet. Do not immerse the pump
and motor!

IN

OUT

Discharge hose or
plastic pipe

1" NPT to
Hose Adapter

Reinforced Inlet Hose
or Plastic Pipe

Figure 1: Install the adapters and connect the inlet and
discharge hoses.