Sanitaire S647 Series User Manual
Page 6
6
Brush Roll
The rotating brush roll sweeps and combs the carpet nap.
Keep the brush roll free from hair and threads so it will
continue brushing. When the bristles of the brush roll no
longer touch a straight edge held across the bottom plate,
the brush roll is ineffective because the bristles no longer
touch the carpet nap. To maintain the most effective cleaning,
replace the wood brush roll. Install new brush strips on the
chromed steel brush roll (refer to instructions).
How To Replace Worn Brush Strips, PN 52282-4
(chromed steel brush roll)
CAUTION: Turn off the switch and unplug the electrical
cord before replacing brush strips.
New brush strips are supplied in sets of two, one long and
one short. To replace, remove bottom plate and belt (see
How To Change Belt). Then, grasp center of brush roll and
lift to remove.
G. Slide in new brush strip of same
length (rounded end fi rst). Fit track
on either side into brush roll slot.
Re place second brush strip from
op po site end of brush roll.
F. Replace shaft.
E. Align indentation on bearing retainer
with brush strip on both ends of
brush roll.
D. Replace shaft washer.
C. Position end cap with flat sides
of center hole over flat sides of
thread ed shaft.
B. Tighten locknut.
A. Align holes and secure rubber end
cap cover flat side against end
cap.
A. Remove rubber end cap cover
(avail able on select models)
from one end.
B. Unscrew locknut.
C. Remove end cap.
D. Remove shaft washer (not
included in ball bearing brush
roll).
E. Remove bearing retainer.
F. Push shaft through opposite
end.
G. Pull out worn brush strip with
pliers.
When properly assembled, the brush roll should rotate freely
between the two end caps. Check the condition of the belt;
change if necessary. Replace the brush roll, belt, and bottom
plate (see How To Replace A Worn Belt).
Ask for GENUINE EUREKA replacement brush strip.
12 inch No. 52282-4.
E
G
F
Note:
Shaft washer (D) not included in ball bearing brush roll as sem bly.
A B C D E
Headlight Bulb
(Standard on most models)
CAUTION: Turn off the switch and unplug the electrical
cord before replacing headlight bulb.
Headlight style varies by model. Locate the notches that
release the tabs at either (1) top, (2) side, or (3) bottom of
the lens, as illustrated. Place a screwdriver into one notch;
twist or pry the screwdriver to release the lens. Repeat for
the second notch on the opposite side.
Rotate the bulb socket forward. Push bulb in and turn to
remove. Secure new bulb into socket and rotate bulb socket
backward.
Replace the lens tabs into the top or the bottom of the hood
opening. Rotate lens to position and press down at each
notch until the lens locks into position.
CAUTION: Use 25 watt replacement bulb, only.
Ask for GENUINE EUREKA replacement bulb, 40009A.
1
2
3
Cleaner Care
CAUTION: Turn off the switch and
unplug the electrical cord
before cleaning unit.
To keep the vacuum cleaner looking new,
it can be wiped with a damp cloth and
a mild soap solution, then thoroughly
dried. Never use any type of chemical
as chemicals can damage the cleaner.
When not in use, the cleaner should be
stored in a clean, dry place.