Sanitaire S647 Series User Manual
Page 5
5
Micron Filter
®
Bag Care
(Micron Filter Bag is standard on some models)
Because the Micron Filter Bag is an effective fi lter medium,
occasionally trapped dust particles will need to be cleaned
from the inside of it. The dust accumulation can be vacuumed
out with another vacuum or the bag may be removed to shake
out. If you desire, the bag may be hand laundered. The zipper
on the bag should be down and the bag should remain right
side out. Use warm water (150°F 65°C) and a mild detergent.
Pre-soaking the bag in a laundry pre-soak is desirable for
best cleaning results. Air dry thoroughly before using.
DO NOT USE AN AUTOMATIC WASHER OR DRYER as
either will cause abrasion to the delicate polyester fabric. DO
NOT DRY CLEAN as dry cleaning fl uids will damage plastic
parts of your bag assembly.
Cleaner Care
CAUTION: Turn off the switch and unplug the electrical
cord before cleaning unit.
To keep the vacuum cleaner looking new, it can be wiped with
a damp cloth and a mild soap solution, then thoroughly dried.
Never use any type of chemical as chemicals can damage
the cleaner. When not in use, the cleaner should be stored
in a clean, dry place.
Brush Roll Belt
The brush roll belt on the upright vacuum cleaner drives the
brush to agitate, sweep, and comb the carpet nap. The belt
should be checked regularly to be sure it is in good condition.
Replace the belt if it is stretching, cracking, or slipping. Cut
away any hair or thread wound around the brush roll or the
belt pulley because the buildup could cause the belt to rotate
unevenly.
How To Replace A Worn Belt
PN 52100A, Style RD
CAUTION: Turn off the switch and unplug the electrical
cord before replacing belt. Belt pulleys can
become hot during normal use. To prevent
burns, avoid touching the belt pulley when
servicing the drive belt.
IMPORTANT: Improper installation of the brush roll
or brush roll belt could cause carpet or
cleaner damage.
1. Release cam locks.
2. Pull up on belt to rotate it off the motor pulley. Lift up
on brush rolL and remove worn belt.
Motor
Pulley
2
Check for brush wear (see Brush Roll instructions).
3. Place new belt around brush roll.
4. Align brush roll pulley with belt guide.
Metal Brush Roll only.
Place rubber end cap covers (available on select models)
over both end caps (fl at side against end cap). Align holes
and secure.
5. Slant brush roll forward so end caps are in line with
slots in cleaner base.
6. Push brush roll into base.
7. Place lower side of belt into belt guide and pull to
stretch the belt around the left side of motor pulley.
Rotate pulley to secure belt into groove.
8. Place slots of bottom
plate over tabs of cleaner
base.
9. Seat and secure cam
locks.
Ask for GENUINE EUREKA
replacement belts, No. 52100A
Look for the symbol.
Look for the symbol.
GEN U INE
EUREKA PRODUCT
Look for the symbol.
Look for the symbol.
7
6
5
8
8