General Information

4

DESCRIPTION

This submersible pump is designed for use as a
waterfall/fountain or as a utility pump. The unit is
equipped with a 3-prong grounding-type power cord.
Ball bearings on the motor shaft never need lubrication.
Automatic reset thermal protection.

SPECIFICATIONS

Power supply required..................................115V, 60 HZ.
Motor duty .....................................................Continuous*
Liquid temperature range ...............32°F to 77°F (0°-25°C)
Individual branch circuit
requirement (minimum) .......................................15 Amps
* For continuous operation the water depth must be at
least 5” (13 cm) to prevent the motor from overheating.
NOTICE: Not designed for applications involving salt
water or brine! Use with salt water or brine will void
warranty.

For parts or assistance, call Simer Customer Service at

1-800-468-7867 / 1-800-546-7867

GPH (LPH) AT TOTAL FEET (M)

No Flow

Motor

0

5

10 15 20

At Height

Model

HP

(0 m)

(1.5 m)

(3 m)

(4.6 m)

(6.1 m)

Shown Below

2430

1/3

2,400 (9,085) 1,920 (7,628) 1,380 (5,224)

780 (2,953)

240 (908)

22’ (6.7 m)

PERFORMANCE

Motor

Minimum

Pumps

Motor Full Load

Circuit

Down

Model

H.P.

Amps

Req. (Amps)

To

2430

1/3

2.3

15

7/8” (22 mm)

Pump

Model No.

Included Adapters

1-1/4” FNPT x 1-1/4”

2430

Hose Barb Elbow (P/N 007-022)

1-1/4” FNPT x 3/4”

Garden Hose Fitting (P/N ZA000900)

DISCHARGE FITTINGS CHART