beautypg.com

Troubleshooting guide, Dimensional specifications – SeaLand VACUUM HOLDING TANK User Manual

Page 7

background image

7

TROUBLESHOOTING GUIDE

6. Pump running too slow,

overheating, blowing

fuses or circuit breakers.

7. Difficulty in emptying

waste from holding
tank.

8. Pump emits odor.

9. System emits odor.

a. Improper voltage.
b. Loose or broken electrical

wiring.

c. Improper wire size.

d. Gear motor worn or defective.
e. Tank is overfilled – air pump

forced to pump water.

a. The dockside pump is very

weak and has low suction

capability.

a. Worn, torn, or punctured

pump diaphragm.

a. Check for improper flexible

hose.

a. Check input power for low voltage.
b. Tighten or reconnect wires.

c. Wire size too small – check

electrical diagram for proper wire
size for voltage of pump used.

d. Check motor and replace if necessary.
e. Disassemble air pump and empty out water.

a. Turn off the power to the VHT system. Flush

the toilet, releasing all the stored vacuum. Begin

pumping out. Repeat flushing if the dockside pump
begins having trouble emptying out the waste.

a. Replace pump diaphragm.

a. Replace hose where necessary. Replacement

hose should be marked “OdorSafe.”

Possible Cause

Service Instructions

Problem

Important Owner Information: OdorSafe

®

Sanitation Hose is formulated for transfer of sanitary waste

only. Do not allow the following items in system: Strong acids or caustic chemicals (example: drain open-
ers), petroleum solvents or fuels, alcohol-based products (example: alcohol-based antifreeze), pine oil-
based products (example: Pinesol

®

cleaner). Use of products containing these substances will void

warranty on hose.

DIMENSIONAL SPECIFICATIONS