beautypg.com

About warning indicators, Actions to be taken for warning mode – JVC Procision DLA-HD990 User Manual

Page 47

background image

ENGLISH

47

Getting Started

Preparation

Basic Operation

Troubleshooting

Settings

Others

About Warning Indicators

The accumulated lamp time or warning mode of this unit is displayed by the indicators.

For information on indicator display during normal operation, see “Controls and Features”. ( P12)

No.

Indicator

Blinking

Time

Blinking

Frequency

Interval

between

Blinks

Content

WARNING LAMP STANDBY/ON

1

-

-

Light on (Red)

-

-

-

During standby

Indicator

display

in normal

conditions.

2

-

-

Light on

(Green)

-

-

-

When the power on

(Hide Off)

3

-

-

Blinking

(Green)

0.5

second

continuous

-

When the power on

(Hide On)

4

-

-

Blinking (Red)

0.5

second

continuous

-

During cool down

5

-

Light on

(orange)

-

-

-

-

Lamp replacement is near (

P48 to 50)

(When accumulated lamp time has

exceeded 2900 hours)

6

-

Light on

(orange)

-

-

-

-

Lamp has reached the end of life

(

P48 to 50)

(When accumulated lamp time has

exceeded 3000 hours)

7

Light on

(Red)

Blinking

(orange)

-

0.25

second

1 time

0.75

second

Lamp does not light up and unit is

unable to project

8

0.25

second

2 times

0.75

second

Lamp is turned off during projection

9

0.25

second

3 times

0.75

second

Lamp cover is removed

10

Blinking

(Red)

-

-

0.25

second

1 time

0.75

second

Abnormalities in the power supply

11

0.25

second

2 times

0.75

second

Cooling fan stops

(cooling fan gets caught)

12

0.25

second

3 times

0.75

second

Internal temperature is too high

(abnormal internal temperature)

13

0.25

second

4 times

0.75

second

External temperature is too high

(abnormal external temperature)

14

0.25

second

1 time

0.75

second

Abnormal electrical circuit

(abnormal startup of drive circuit)

Blinking

(orange)

15

0.25

second

2 times

0.75

second

Abnormal electrical circuit

(abnormal communication of the

drive circuit)

16

0.25

second

3 times

0.75

second

Abnormal electrical circuit

(abnormal drive circuit of image)

17

0.25

second

4 times

0.75

second

Abnormalities in the automatic lens cover

Actions to Be Taken for Warning Mode

When the unit enters into warning mode (No. 7 to 17), it will automatically stop projection, and run the cooling

fan for about 60 seconds.

After the cooling fan has stopped, pull out the power plug from the power outlet.

Then, follow the procedures below.

No.

Check

Action

7

Check that an impact shock has not occurred during operation.

Check that the lamp unit and lamp cover are correctly installed.

Check that nothing is blocking the auto lens cover.

Turn on the power again.

8

9

17

10

Check that nothing is blocking the air inlets.

Check that the external temperature is normal.

Leave the unit until it cools down.
After that, turn on the power again.

11

12

13

14

15

16

If the warning indication is displayed again, please wait for the cooling fan stopped, then pull out the power plug from the power outlet.

Then call your authorized dealer for repair.

This manual is related to the following products: