beautypg.com

Jotul GF 3 BV User Manual

Page 16

background image

INSTALLING THE OPTIONAL

BLOWER:

IMPORTANT: IF THE OPTIONAL FORCED AIR

BLOWER KIT (part # 129161) IS TO BE INSTALLED

ON THE STOVE AT THE TIME OF THE

INSTALLATION OR IN THE FUTURE, THE GAS

SUPPLY LINE SHOULD BE INSTALLED AS

CLOSE TO THE FLOOR AS POSSIBLE. USE OF A

90° ELBOW DIRECTLY OFF THE VALVE WILL

ALLOW FOR PROPER CLEARANCE FOR THE

BLOWER.

Mounting the blower:

1. Locate the reflector sheild (28) on the back of

the stove. Remove the cover plate from the

reflector shield to allow the blower bracket to

slide under the stove.

2. Locate the two raised bosses on the bottom plate

(back) of the stove.

3. The blower is mounted to the stove using these

two threaded holes.

4. With the blower bracket and sensor facing upward

align the two middle mounting holes on the bracket

with the two threaded holes on the bottom of the

stove. See Figure 10.

5. Use the two 6mm bolts to attach the blower to

the stove.

6. Be sure to tighten the bolts so that the blower is

drawn upward and tight against the stove bottom.

7. The heat sensor (thermodisc), that is already

attached to the blower bracket, should be inserted

under the stove bottom and make contact with

the firebox! See Figure 10.

16

Connecting the blower wiring harness:

1. Lift off the stove top plate.

2. Loosen (

BUT

DO

NOT

REMOVE

) the 10mm bolt

holding the switch box to the side of the stove

(left rear corner of the stove), and lift out the

switch box.

3. Remove the “blank” switch from the box.

(Hint: break the retaining tabs holding the

switch in the box.)

4. Insert the new HI/OFF/LO switch into the

box.

5. Connect the insulated wires from the blower

to three leads on the HI/OFF/LO switch.

BLACK wire to the HI position, WHITE

wire to the OFF position, and the RED wire

to the LO position. See Figure 11.

6. Retighten the switch box to the side of the

stove. Be sure all wires are unobstructed.

7. Replace top plate.

REMINDER:

The blower will ONLY come on when the

switch is in the Hi or Lo position and ONLY

when the sensor (thermodisc) is heated by the

stove.

(Approximately 10 - 20 minutes after the stove

has been running).

7G68FCDÃ

S@9GPXÃ

XCDU@PAAÃ

Figure 11

Middle mounting holes.

Use these holes to mount

blower.

Sensor

(thermodisc)

Direction

under the

stove.

Figure 10