6
Ground Terminal (GND)
Make the ground lead as short as possible, leaving enough length to complete 
the installation and to allow for any service that may be needed at a later date. 
To ensure a good ground, scrape away any paint or undercoating to expose 
bare metal. Use a "ring" terminal of the proper gauge and an "outside star 
washer" (between the chassis and ring terminal) when making your ground 
connection. Although you’ve scraped away the paint to expose bare metal, the 
outside star washer will help to "bite into" the chassis for a tight, secure 
ground.
Replacement Fuse Requirements (FUSE)
Model
Quantity
Amps
Type
420
2
15
ATO
480
2
25
ATO
900
3
30
ATO
1150
4
30
ATO
1302
1
60A
MAXI
1304
1
80A
MAXI
Drill hole in chassis sheet metal.