7.3. Jumper Settings

Caution on Jumper Setting.

Before making any mode or jumper setting turn the power OFF.

Jumpers for mode setting are found on the boards PK8054 & PK8057.

The following modes are available with jumper setting:

Input/Output Mode of HD/VD signal. (HD/VD input is factory setting)
Edge Pre-select Mode. (Factory setting)
Pulse Width Control Mode
Start/Stop Trigger Mode
Long Time Exposure Mode

Set the jumpers according to the list below in 7.3.1. and 7.3.2.
The jumper positions are shown in “7.4.1. Board 8054 Side B” and “7.4.2. Board 8057 Side A”.
Switch SW2 on PK8057 is shown in “7.2. SW2 on PK8057 Board”.

Jumper

HD/VD in/out

External trigger modes

Remarks

Ext.

HD/VD

input *)

Int.

HD/VD

output

Edge pre-

select

Pulse

width

control

Start/

stop

trigger

Long time

expose

JP1

Short

Open

Short

Short

Short

Short

HD input /output. Factory set input
HD input /output. Factory set input

JP2

Open

Short

Open

Open

Open

Open

JP3

Short

Open

Short

Short

Short

Short

VD input /output. Factory set input
VD input /output. Factory set input

JP4

Open

Short

Open

Open

Open

Open

JP5

Short

Short

Short

Short

Short

Short

JP6

Open

Open

Open

Open

Open

Short

Long time integration

JP7

Short

Short

Short

Short

Open

Short

JP8

Open

Open

Open

Open

Short

Open

JP9

Open

Open

Open

Open

Short

Open

JP10

Open

Open

Open

Open

Short

Open

JP11

Open

-

-

-

-

-

Pixel clock out. Factory set OPEN

JP12

Short

Short

Short

Open

Short

Short

Pulse width

SW2-1

ON

-

ON

ON

ON

ON

HD in 75 Ohm term. Factory set ON

SW2-2

ON

-

ON

ON

ON

ON

VD in 75 Ohm term. Factory set ON

Jumper

HD/VD in/out

External trigger modes

Remarks

Ext.

HD/VD

input *)

Int.

HD/VD

output

Edge pre-

select

Pulse
width

control

Start/

stop

trigger

Long time

expose

R127

Short

Short

Short

Short

Open

Short

Factory set SHORT

7.3.1. Jumper on PK8054 Board

*) Factory Setting

7.3.2. Jumper on PK8057 Board

*) Factory Setting

7.3.3. Pixel Clock Output
To use pixel clock output (TTL level: 4.0 V), make the jumper JP11 on PK8057 board shorted-circuited. The
jumper position is shown in “7.4.1. Board PK8057 Side A”.
Pixel clock pulse will be output from pin no.9 of 12-pin multi-connector.

Caution for Pixel Clock Output.

When the pixel clock is enabled, it may cause interference with external equipment if it not properly