beautypg.com

0 wiring diagram, j-380 models (usa/canada 60hz), 0 wiring diagram (60hz j-380 model), 0 wiring diagram – Jacuzzi ProTech LCD User Manual

Page 50: Page 46

background image

Page 46

17.0 Wiring Diagram

J-380 Models (USA/Canada 60Hz)

SENSORS

Power Input: 240 V

AC, 60A

/ 50A

/ 40A

1 PHASE, 60Hz; USE MIN. 6

A

WG (10 mm

2

)

COPPER CONDUCT

ORS ONL

Y

J4

J8

J2

K8

K6

K5

K4

K1

K2

K3

K7

J1

Z1

J6

J7

J3

OPTIONS

FLOW SWITCH

HI - LIMIT

/ FREEZE SENSOR

TRANSFORMER

T1

RED

Red

Wht

Wht

Wht

Blk

Blk

Red

Blk

BLK

Blk

20A, 250V

MDA20

F2

PUMP

3

PUMP

1

T92

Relay

HI

Wht

Wht

Blk

Blk

PUMP

2

HI

HI

LO

TB3

TB2

TB6

TB1

TB1

GRN

1

3

5

6

8

10

1

2

1

2

JP20

JP19

JP9

1

1 3 5 7 9

1 3 5 7 9

11 13

TEMPERA

TURE

SENSOR

To

Heater &

Pump 2 Relay

From

TB1

SP

A

LIGHT

TB5

From TB1

30A,

250V

SC-30

F1

UV or CD

Ozonator

(Optional)

INTERLOCK

JUMPER

Circulation

Pump

STEREO

(Optional)

This device complies with part 15 of

the FCC rules. Operation is subject to

the following two conditions:

1.

This device may not cause harmful

interference.

2.

This device must accept any

interference received including

interference that may cause

undesired operation.

Power Supply

Remote Panel

Main Panel

HEA

TER

5.5 kW

Select

Cycle

Mode

Display

y

y

Change

Filter