Electrical connections, Electrical requir, Suppl – John Lewis JLBIGH702 User Manual
Page 7
![background image](/manuals/131402/7/background.png)
7
Electrical Connections
Electrical Connections
Electrical Connections
Electrical Connections
Electrical Connections
THIS HOB MUST BE EAR
THIS HOB MUST BE EAR
THIS HOB MUST BE EAR
THIS HOB MUST BE EAR
THIS HOB MUST BE EARTHED
THED
THED
THED
THED.....
Any electrical work required to install this hob should
be carried out by a qualified electrician or competent
person, in accordance with the current regulations.
Electrical Requir
Electrical Requir
Electrical Requir
Electrical Requir
Electrical Requirements
ements
ements
ements
ements
Any permanent electrical installation must comply with the
latest I.E.E. Regulations and local Electricity Board
regulations. For your own safety this should be undertaken
by a qualified electrician, e.g. your local Electricity Board,
or a contractor who is on the roll of the National Inspection
Council for Electrical Installation Contracting (NICEIC).
Electrical Connections
This hob is designed to be connected to a 230 V 50 Hz AC
electrical supply.
Before switching on, make sure the electricity supply voltage
is the same as that indicated on the hob rating plate. The
rating plate is located on the bottom of the hob. A copy is
attached on the back cover of this book.
The hob is supplied with a 3 core flexible supply cables.
This has to be provided with a proper plug, able to support
the load marked on the identification plate. To connect the
plug to the cable, follow the recommendation given in diagram
aside. The plug has to be fitted in a proper socket.
In the event of having to change the fuse, a 3amp ASTA
approved (BS 1362) fuse must be used.
Should the plug need to be replaced for any reason, the
wires in the mains lead are coloured in accordance with the
following code:
Green and Yellow
- Earth
Blue
- Neutral
Brown
- Live
— Connect the green and yellow (earth) wire to the
terminal in the plug which is marked with the
letter 'E' or the earth symbol
or coloured green
and yellow.
— Connect the blue (neutral) wire to the terminal
in the plug which is marked with the letter 'N' or
coloured black.
— Connect the brown (live) wire to the terminal in
the plug which is marked with the letter 'L' or
coloured red.
Upon completion there must be no cut, or stray strands of
wire present and the cable clamp must be secure over the
outer sheath.
A cut off plug inser
A cut off plug inser
A cut off plug inser
A cut off plug inser
A cut off plug inserted into a 13 amp sock
ted into a 13 amp sock
ted into a 13 amp sock
ted into a 13 amp sock
ted into a 13 amp socket
et
et
et
et
is a serious saf
is a serious saf
is a serious saf
is a serious saf
is a serious safety (shock) hazar
ety (shock) hazar
ety (shock) hazar
ety (shock) hazar
ety (shock) hazard.
d.
d.
d.
d. Ensur
Ensur
Ensur
Ensur
Ensure that
e that
e that
e that
e that
the cut off plug is disposed of saf
the cut off plug is disposed of saf
the cut off plug is disposed of saf
the cut off plug is disposed of saf
the cut off plug is disposed of safel
el
el
el
elyyyyy.....
P
PP
PPermanent Connection
ermanent Connection
ermanent Connection
ermanent Connection
ermanent Connection
In the case of a permanent connection, it is necessary that
you install a double pole switch between the hob and the
electricity supply (mains), with a minimum gap of 3 mm
between the switch contacts and of a type suitable for the
required load in compliance with the current electric
regulations.
The switch must not break the yellow and green earth cable
at any point.
Ensur
Ensur
Ensur
Ensur
Ensure that the hob suppl
e that the hob suppl
e that the hob suppl
e that the hob suppl
e that the hob supply cable does not
y cable does not
y cable does not
y cable does not
y cable does not
come into contact with surfaces with
come into contact with surfaces with
come into contact with surfaces with
come into contact with surfaces with
come into contact with surfaces with
temperatur
temperatur
temperatur
temperatur
temperatures higher than 50 deg.
es higher than 50 deg.
es higher than 50 deg.
es higher than 50 deg.
es higher than 50 deg. C
C
C
C
C .....
Min. size Cable/flex
Min. size Cable/flex
Min. size Cable/flex
Min. size Cable/flex
Min. size Cable/flex
Cable / flex type
Cable / flex type
Cable / flex type
Cable / flex type
Cable / flex type
Fuse
Fuse
Fuse
Fuse
Fuse
0.75 mm
2
H05 V2V2-F (T90)
3 A
Suppl
Suppl
Suppl
Suppl
Supply cable r
y cable r
y cable r
y cable r
y cable replacement
eplacement
eplacement
eplacement
eplacement
The cable used to connect the hob to the electrical supply
must comply to the specifications given below.
Neutral
Neutral
Neutral
Neutral
Neutral
Earth (yellow/green)
Earth (yellow/green)
Earth (yellow/green)
Earth (yellow/green)
Earth (yellow/green)
The manufacturer declines any liability should
The manufacturer declines any liability should
The manufacturer declines any liability should
The manufacturer declines any liability should
The manufacturer declines any liability should
these safety measures not be observed.
these safety measures not be observed.
these safety measures not be observed.
these safety measures not be observed.
these safety measures not be observed.