Cv-a1-20 rs-232c command list, Cv-a1-20 – JAI CV-A1-20 User Manual
Page 19
CV-A1-20
7.2. CV-A1-20 RS-232C command list.
Command Name
Format
Parameter
Remarks
A – General settings and useful commands
EB Echo Back
EB=[Param.]
1=Echo on
Off at power up
ST Camera Status request ST?
Actual setting
HP Online Help request HP?
Command list
VN Firmware version
VN?
3 letter version
ID
Camera ID request
ID?
10 characters *3)
MD Model name request
MD?
≤10 characters *3)
UD User ID
UD=[Param.]
≤16 characters *3)
B – Timing and shutter related commands
SC Scanning format
SC=[Param.]
2=1/3 partial
1=1/2 partial
3=1/6 partial
TR Trigger mode
TR=[Param.]
2=Pulse width
4=Long time
6=Smearless
1=Edge
3=Frame delay
5=Start/stop
SM Shutter mode
SM=[Param.]
SH Shutter speed
SH=[Param.]
2=1/42
4=1/175
6=1/698
8=1/2794
10=1/14,000
12=1/56,000
14=1/112,000
1=1/21
3=1/70
5=1/349
7=1/1397
9=1/5587
11=1/28,000
13=1/84,000
15=1/140,000
All16 step is valid
in normal trigger
mode.
In all trigger
modes shutter
speeds higher
than 9 will result
in 1/8381
PE Programmable expos.
PE=[Param.]
0=1.3 H,
1=1.3H
1023=1023.3 H
H= 83.6 µsec
BI
Binning
BI=[Param.]
0=off
2=horizontal
1=vertical
3=hor. + ver.
*1)
HC HD accumulation
HC=[Param.]
accumulation
1=a-synchron
accumulation
a-sync. only for
TR=1 and TR=3
C – Signals and polarity
SO Sync signal
SO=[Param.]
1=sync on video
PC Pixel clock
PC=[Param.]
1=clock out
Should be off
when not used
EW EEN/WEN
EW=[Param.]
1=WEN out
Pin#6 on 6 pin
TP Trigger polarity
TP=[Param.]
1= active high
*2)
WP WEN polarity
WP=[Param.]
1= active high
D – Gain and analogue signals setting
AS AGC Switch
AS=[Param.]
1=AGC on
0= manual gain
AG AGC Level
AG=[Param.]
Range 0 to 255
GA Manual gain Level
GA=[Param.]
Range 0 to 255
RP Rear Potentiometer
RP=[Param.]
1=rear potm.
SU Setup Level
SU=[Param.]
Range 0 to 255
WC White clip Level
WC=[Param.]
Range 0 to 255
GS Gamma Select
GS=[Param.]
1=gamma 0.45
E – Saving and loading data in EEPROM
LD Load settings from
camera EEPROM
LD=[Param.]
2=User 2 area
1=User 1 area
3=User 3 area
Latest used data
area becomes
default at next
power up
SA Save settings to
camera EEPROM
SA=[Param.]
3=User 3 area
2=User 2 area
EA EEPROM area request
EA?
Return latest used
area
*1)
The internal pixel clock is not changed in H binning (BI=2 and BI=3). To keep the aspect ratio correct, divided the clock by
2 in the frame grabber.
*2)
If positive logic is used (TP=1), the first trigger pulse after power up will be ignored.
*3)
Functions implemented from s/no E121231.
- 18 -