6.5. Edge Pre-select Mode

The exposure starts at the first HD pulse after the trigger leading edge. It stops and is read out
after the duration of the shutter time selected. It can be the first 9 step in normal or 1023 steps
in programmable shutter. SM=0 or SM=1. Shutter selections SH ≥10 will result in 1/8381 sec. This
mode will operate with full and partial scanning and with all binning modes. Partial scanning
together with binning will work, but it is not described, and no timing diagrams are documented.
An EEN pulse will indicate the active accumulation time, and a WEN pulse indicates that the
resulting video is being read out.


To use this mode:
Set function:

Trigger mode “Edge Pre-select”

TR = 1

Shutter mode “Normal” or “Programmable”

SM=0, SM=1

“Shutter Speed”

SH=0 through 9

“Programmable exposure”

PE=1 through 1023

Polarity and other functions

Input:

Ext. trigger to pin 5 on 6 pin connector (or pin 11 on 12-pin connector).

Ext. HD to pin 6 on12-pin connector. (If used).

Important notes on using this mode.

• The start of exposure will start synchronized to the internal H signal. The start may be

shifted max 1H. To avoid this shift (1 H jitter), synchronize the camera to an external HD
and make sure that the trigger pulse aligns to the HD as shown in fig. 17.

• The duration of the trigger should be >1H to <2000H.
• A new trigger must not be applied before WEN is high.
In trigger modes there are no continuous VD out, only after each trigger input.

1H = 83.6 µs

No equalize and serration pulses.


Table showing the figures for the different modes.

Scan mode

A

B

C

CCD array line #

D

Effective video

E

Max frame rate

fps

Remarks

Full

10H 14H 4 to 1038

1035H

18H

11

1/2 Partial

17H 33H 271 to 783

513H

25H

20

1/3 Partial

17H 33H 357 to 697

341H

25H

28

1/6 Partial

17H 33H 442 to 612

171H

25H

46

H binning

10H 14H 4 to 1038

1035H

18H

11

V binning

10H 14H 18

to

1019

501H

18H

22

V+H binning 10H 14H 18

to

1019

501H

18H

22

Fig. 20. Timing for Edge Pre-select with partial scanning and binning.