Chromatherapy: Installation and Operation

Page of 5

GQ99000 • 07-08

Figure 8. Hole for Chromatherapy Lamp(s)

Lamp

assembly

Inside surface

of bath shell

Retainer

nut

Hole,

1-1/16”

Apply silicone

behind panel

Figure 7. Attach plug to Chromatherapy device

Bath shell (Outisde of bath)

Chromatherapy

lamp or control

panel (Inside of

bath)

Plug from control

panel or lamp

3.

Remove any and all burrs or roughness from the inside of

the hole.

Clean away all debris and tools from the area. Use a moist cotton

cloth to wipe the inside and shelf of the bath rim.

INSTALL PANEL AND LAMP(S)

Install the control panel and each lamp as described below.

Mount Control Panel

The hole for the control panel has a notch to ensure proper

mounting alignment of the control panel on the bath, see Figure 6.
1.

Apply clear silicone to the back side of the control panel and

insert the panel into place.

Caution: Do not permit silicone to enter the plug area at the

back of the panel. Failure to comply may result in damage to the

equipment.
2.

Press the panel fast against the inside surface of the bath.

Make sure the panel is pressed completely against the

shell.

3.

Remove excess silicone from around the control panel.

4.

Alow the silicone to cure to ten to fifteen minutes

undisturbed.

5.

Attach the control cable from the control panel to the control

box, see Figure 7. The proper plug for the control panel is

shown in Figure 5.

Mount Chromatherapy Lamp(s)

The hole is ready to mount the lamp(s), see Figure 8.
1.

Remove the retainer nut from the lamp assembly.

2.

Apply clear silicone around the back of the edge of the

lamp.

Caution: Do not permit silicone to enter the plug area at the

back of the lamp. Failure to comply may result in damage to the

equipment.
3.

Insert the lamp housing through the hole in the bath shell

so that the edge of the lamp housing is tightly against the

inside surface of the bath. Make sure the lamp is pressed

completely against the shell to prevent leakage.

4.

From the outside of the bath shell, screw the retainer nut

over the threaded body, as shown in the figure. Hand-

tighten the retainer nut onto the lens threads. Do not permit

the lamp to rotate while tightening the retainer nut.

5.

Remove any excess silicone from around the lamp.

6.

Allow the silicone to cure for ten to fifteen minutes.

7.

Attach the light cable from the back of the lamp to the

control box see Figure 7. The proper plug for the lamp(s) is

shown in Figure 5.

note: There are four plugs for up to four lamp cables. Any of the

four plugs can be used for proper operation. Jacuzzi recommends

that you start with the left-most plug, closest to the control box

cable plug to attach each lamp.

Figure 6. Mount the Control Panel

Control

panel

Modular

cable

Apply silicone

behind panel

Hole for control panel