JVC VR 601 User Manual
Page 53

53
6. RS-232 & RS-485 Protocol
6.1 Setup
6.1.1 Use a Null Modem cable (the standard RS-232 9 Pin Cable with Pin 2 and Pin 3 exchanged, see pin
configuration chart below for details) to connect the COM 1 on the rear panel of the DVR to a PC.
6.1.2 Set the RS-232 option to ON in the COMMUNICATION page of the setup menu.
6.1.3 Set the PC communication parameters: 9600 bps, No Parity, 8 Data Bits, 1 Stop Bit.
6.2 Communication Protocol:
6.2.0 General Command Format
parameters>, Lead Code = 0x41 Dest ID = 0x01 Src ID = 0x20 Main Category = 0x01 Keys and Signals = 0x02 Command Second Category = 0x01 Handshake = 0x02 Request Time/Set Time = 0x06 Request System State End Code= 0x4f