Technical data, Installation, Positioning – John Lewis JLCH200 User Manual
Page 15: Electrical connection

Technical data
JLCH200
JLCH300
JLCH400
Dimension of the recess
Height
868 mm
876 mm
876 mm
Width
795 mm
1050 mm
1325 mm
Depth
665 mm
665 mm
665 mm
Rising Time
28 h
32 h
31 h
The technical information are situated in the
rating plate on the external right side of the
appliance and in the energy label.
Installation
Positioning
Warning! If you are discarding an old
appliance that has a lock or catch on
the lid, you must ensure that it is made
unusable to prevent young children
being trapped inside.
Important! The appliance shall have the plug
accessible after installation.
This appliance can be installed in a garage or
cellar, but for optimum performance install
this appliance at a location where the ambient
temperature corresponds to the climate class
indicated on the rating plate of the appliance:
Climate
class
Ambient temperature
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
Climate
class
Ambient temperature
T
+16°C to + 43°C
Electrical Connection
Caution! Any electrical work
required to install this appliance should
be carried out by a qualified electrician
or competent person.
Warning! This appliance must be
earthed.
The manufacturer declines any liability
should these safety measures not be
observed.
Important! The wires in the mains lead are
coloured in accordance with the following
code: