Clearance Requirements

Minimum clearances for the GF3 DVII
Allagash

Rear:

4” / 102 mm

Ceiling: 12” / 305 mm
Corner: 4” / 102 mm
Right Side: 4” / 102 mm
Left Side: 10” / 254 mm (required for complete
access of the lighting instructions)

Minimum Clearance for Vent Pipe

Horizontal Runs:

Off the top of the pipe:

2" (50mm)

Off the sides and bottom:

1" (25 mm)

Vertical Runs, all sides: 1" (25 mm)

Corner Installation

Alcove Installation

Minimum Alcove Height:

40” / 1006 mm

Minimum Alcove Width:

38” / 965 mm

(Assumes 10” off the left side and 4” off the right side)

Maximum Alcove Depth:

24” / 607 mm

Pipe Clearances:

1” on vertical runs
2” off top of horizontal runs, 1” on other sides.

Parallel Installation

Mantel and Trim Clearances

A

B

C

Mantel or Trim Depth

24” / 607 mm

18” / 457 mm

5” / 127 mm

Minimum
Clearance from
the Top Plate
A = 12”
B = 9”
C = 4”

Figure 1.

5

Figure 3. Top Exit Centerlines and possible hearth
configuration.

4”

102 mm

4”

102 mm

13 1/2”

337 mm

16”

406

mm

16”

406 mm

27”

686 mm

36”

910 mm

13 1/2”

337 mm

This is not a required
hearth size, although it
is aesthetically
proportional. Assumes
the stove is 4” off the
corners.

4”

102 mm

4”

102 mm

10”

254

mm

Left Side

Right

Side

Figure 2. Allow 10” on left side of the appliance for
complete access to the lighting instructions and
control valve.