Clearance requirements, Corner installation alcove installation, Parallel installation mantel and trim clearances – Jotul GF3 DVII User Manual
Page 7
Clearance Requirements
Minimum clearances for the GF3 DVII
Allagash
Rear:
4” / 102 mm
Ceiling: 12” / 305 mm
Corner: 4” / 102 mm
Right Side: 4” / 102 mm
Left Side: 10” / 254 mm (required for complete
access of the lighting instructions)
Minimum Clearance for Vent Pipe
Horizontal Runs:
Off the top of the pipe:
2" (50mm)
Off the sides and bottom:
1" (25 mm)
Vertical Runs, all sides: 1" (25 mm)
Corner Installation
Alcove Installation
Minimum Alcove Height:
40” / 1006 mm
Minimum Alcove Width:
38” / 965 mm
(Assumes 10” off the left side and 4” off the right side)
Maximum Alcove Depth:
24” / 607 mm
Pipe Clearances:
1” on vertical runs
2” off top of horizontal runs, 1” on other sides.
Parallel Installation
Mantel and Trim Clearances
A
B
C
Mantel or Trim Depth
24” / 607 mm
18” / 457 mm
5” / 127 mm
Minimum
Clearance from
the Top Plate
A = 12”
B = 9”
C = 4”
Figure 1.
5
Figure 3. Top Exit Centerlines and possible hearth
configuration.
4”
102 mm
4”
102 mm
13 1/2”
337 mm
16”
406
mm
16”
406 mm
27”
686 mm
36”
910 mm
13 1/2”
337 mm
This is not a required
hearth size, although it
is aesthetically
proportional. Assumes
the stove is 4” off the
corners.
4”
102 mm
4”
102 mm
10”
254
mm
Left Side
Right
Side
Figure 2. Allow 10” on left side of the appliance for
complete access to the lighting instructions and
control valve.