Export j-350/j-360/j-370 models (50hz), Export j-380 models (50hz) – Jacuzzi LCD Series User Manual
Page 12
Export J-380 Models (50Hz)
230V/40A*
230V/35A**
Voltage:
230 VAC
230 VAC
Number of Wires
3
3
Frequency:
50Hz
50Hz
Current Draw:
32A
26A
Circuit Breaker:
40A
35A
Important Information:
*
In 40A configuration, the heater will operate while any two jets
pumps are running in high speed. Note: jet pumps 2&3 run only in
high speed. This is the factory setting.
** In 35A configuration, the heater will not operate while any two jets
pumps are running in high speed. Note: jet pumps 2&3 run only in
high speed.
All export models can be adapted to use higher amperage circuits when
available. Please contact your dealer for details. The electrical supply for
this product must comply with local electrical regulations.
Export J-350/J-360/J-370 Models (50Hz)
230V/40A*
230V/30A**
230V/20A***
Voltage:
230 VAC
230 VAC
230 VAC
Number of Wires
3
3
3
Frequency:
50Hz
50Hz
50Hz
Current Draw:
29A
23A
15A
Circuit Breaker:
40A
30A
20A
Important Information:
*
In 40A configuration, the heater will operate while both jets pumps
are running in high speed. This is the factory setting.
** In 30A configuration, the heater will not operate when both jets
pumps are running in high speed. Note jets pump 2 runs only in
high speed.
*** In 20A configuration, the heater will not operate while either jets
pump is running in high speed. Note: jets pump 2 runs only in high
speed.
All export models can be adapted to use higher amperage circuits when
available. Please contact your dealer for details. The electrical supply for
this product must comply with local electrical regulations.
Page 8