Introduction, 2/4/6/8/10/12/15-bay product, 2/4/6/8/10/12/15-bay product family features -1 – JMR electronic Fortra 5251F6 User Manual
Page 5

The 15-bay FORTRA
I6 Infortrend 5251F6 enclosures are designed to be used
with a host system to provide a high-end RAID subsystem. The following is a
summary of the 15-bay Rackmount and Tower enclosure features:
•
The 15-bay FORTRA
I6 Infortrend 5251F6 Tower enclosure supports
up to fifteen LP SCA 40-pin SCA drives. This model supports up to six
2Gb/s Fibre Channel loops. The Fibre Channel enclosure has dual or
quad fibre channel host ports and dual or quad fibre channel drive ports.
•
The 15-bay FORTRA
I6 Infortrend 5251F6 Rackmount is a 19" wide,
3U (5-1/4") high rackmount enclosure that supports up to fifteen LP SCA
40-pin drives. All other features are the same as the 15-bay FORTRA
Tower.
2/4/6/8/10/12/15-bay Product Family Features
FORTRA
and
S
Stto
orrB
Bllaad
de
e are families of high-end enclosures designed for
high-volume performance storage solutions. The following table shows the
features of the FORTRA
2/4/6/8/10/12/15-bay and
S
Stto
orrB
Bllaad
de
e products:
1-1
FORTRA
15-bay I6 Infortrend 5251F6 Installation Guide Rev A
1. Introduction
2-bay 4-bay
1,3
6-bay
*1,3
8-bay
1
10-bay
*1,2
12-bay 15-bay
*1,3
StorBlade
Number of Device Bays
2
4
6
8
10
12
15
4
Number of Blowers
1
1
1 or 2
2
2
2
2
2
Number of Power Supplies
1
1
1 or 2
2
2
2
2
1 or 2
Number of I/O Channels (SCSI Only)
1
1
2
2
2
2
2
SCSI SE/LVD Supported
2
2
2
2
2
2
2
Fibre Channel Supported
2
2
2
2
2
2
Hot-Swap Canisters
2
2
2
2
2
2
2
2
Removable Power Supplies
2
2
2
2
2
2
2
Fibre only
Removable Blowers
2
2
2
2
2
2
2
Fibre only
N+1 Power Supplies
2
2
2
2
2
Fibre only
N+1 Blowers
2
2
2
2
2
2
MIA Support (FC Only)
2
2
2
2
Loop Expansion Support (FC Only)
2
2
2
2
2
2
2
Daisy Chainable (SCSI Only)
2
2
2
2
2
2
2
Built-in Termination (SCSI Only)
2
2
2
2
Auto Termination (SCSI Only)
2
2
2
2
SAF-TE/SES Ready (Optional)
2
2
2
2
Fibre only
SAF-TE/SES Compatible
2
2
2
2
Fibre only
SCSI to SCSI RAID Support
2
2
2
2
Fibre to SCSI RAID Support
2
2
Fibre to Fibre RAID Support
2
2
2
Fibre to ATA RAID Support
2
SCSI to ATA RAID Support
2
(D)esktop/(T)ower/(R)ackmount
D
D
DTR
T
TR
R
TR
R
* 6/10/15-bay unit features apply to both Tower and Rackmount models
1 Features are based on a standard configuration with no internal host controller(s) installed
2 Fibre channel 10/15-bay enclosures have built-in SES
3 Fibre Channel 2Gb Model available. 2Gb models use SFP transceivers.