Infortrend 5251f6 install, Installation steps, Default slot id – JMR electronic Fortra 5251F6 User Manual
Page 28: Infortrend 5251f6 installation, Installation steps -1 default slot id -1

9-1
FORTRA
15-bay I6 Infortrend 5251F6 Installation Guide Rev A
This model is designed to be used with up to two 5251F6 RAID bridge controllers
from Infortrend. A total of six loops are provided. The table below indicates the
possible host and disk combinations. RCC is used for inter controller
communication when two controllers are installed. RCC occurs on either a
dedicated loop or shared with a disk loop and is firmware selectable.
Up to two 5251F6 controllers may be installed into the enclosure. All of the I/O
and power connections are made at the rear of the unit. Additionally, the controller
can be removed from the rear of the unit and the power supplies and blowers may
be hot-swapped from the rear of the unit.
Installation Steps
1. Install each controller into the JMR controller canister provided and plug
into the unit.
2. Install up to 15, 3.5" hard disk drives into the device canisters using 4 screws
per device (screws have been provided - JMR P/N HDS-01906) and install
into the front of the unit. (Refer to
3. Plug in the two AC power cords to the AC inlet located on each power
supply in the rear of the unit. Turn the power supplies on using the on/off
switch located on each power supply.
4. Connect the RS-232 port to the unit and configure the RAID set. See
for connector location and use.
5. Connect the host I/O ports to a HBA or hub/switch and connect any
expansion I/O ports to other devices. (Refer to
Default Slot ID
for default slot IDs.
9 . I n fo r t r e n d 5 2 5 1 F 6 I n s t a l l at i o n
# of Host
Ports
# of Disk
Ports
RCC
4
2
Shared with drive loop
2
4
Shared with drive loop