Completely insert 3/8" polyethylene tubing from the outlet side of filter head into the 3/8" to
1/4" divider ("Y" quick-connect fitting). This divider allows the system to supply one or two
plumbing fixtures with filtered water.
To connect one plumbing fixture:
Completely insert the plumbing fixture's 1/4" copper tubing into one of the outlets of the "Y"
fitting. In the other outlet of the "Y" fitting, insert the provided plug.
To connect two plumbing fixtures:
Completely insert both plumbing fixture's 1/4" copper tubes into both outlets of the "Y" fitting.
Discard the provided plug.
To remove a tube from its quick-connect fitting, depress the release ring
into the fitting and gently pull the tube away from the fitting.
3. Make Plumbing Connections ( continued)
4. Connect to Cold Water Supply Line
Supplied with the unit is a brass nut, ferrule and tube insert to
connect the polyethylene tube from the input side of the filter
to a standard 3/8" compression fitting. Other plumbing
connections are possible – check with a qualified plumber
should you have questions.
Slide the nut and ferrule over the tube and then push in the
tube insert. Insert the tube into a standard 3/8" compression
fitting (not supplied) and tighten. Be careful not to overtighten.
Note: Connect the filter to the cold water supply only.
5. Test the Water Connection
Test the water connection to see if it is watertight. If it is not, relieve water pressure by
turning off the water supply, and adjust or tighten fittings as necessary.
43386 Filter Owner's Manual.qxd 9/26/02 11:58 AM Page 6 Greg Leber Jobs:39237 ISE HWD Owner's Manual:43386 HWD Filter