Ice series refrigeration system – Ice-O-Matic ICE0250 Series User Manual
Page 72

ICE Series
Refrigeration System
Page E19
ICE0806W
Ambients
Refrigeration Pressures PSIG
Compressor Temps
°F
Cycle Times
°F
Discharge Suction Discharge
Suction
Minutes'
Seconds"
Air/Water
Start
End
Start Freeze
End Freeze
Start
Harv
End
Harv
Start End Start End Freeze Harvest Complete
70/50 250
250 59
34
72
76 103
159
43
27
8'36"
2'01"
10'37"
90/70 250
250 61
34
79
88 105
165
49
32
10'52"
1'10"
12'02"
110/100 321
293
78
35
108
121 116
193
65 45 18'32" 0'55" 19'27"
ICE0806R
Ambients
Refrigeration Pressures PSIG
Compressor Temps
°F Cycle
Times
°F
Discharge Suction Discharge
Suction
Minutes'
Seconds"
Air/Water
Start
End
Start Freeze
End Freeze
Start
Harv
End
Harv
Start End Start End Freeze Harvest Complete
-20/40 240
240 61
29
100 108 100
160
51
41 9'46" 1'06" 10'52"
70/50 285
265 68
36
115 122 108
170
60
45
9'31"
1'00"
10'31"
90/70 294
272 72
35
118 125 111
177
63
46
11'12"
0'56"
12'08"
110/100 401
326
90
33
136
160 120
216
79 57 22'34" 0'50" 23'24"
ICE1006A
Ambients
Refrigeration Pressures PSIG
Compressor Temps
°F
Cycle Times
°F
Discharge Suction Discharge
Suction
Minutes'
Seconds"
Air/Water
Start
End
Start Freeze
End Freeze
Start
Harv
End
Harv
Start End Start End Freeze Harvest Complete
50/40 186
176 50
33
70
68 100
132
41
35
4'48"
1'56" 6'44"
70/50 233
210 56
30
78
82 104
152
46
32
8'00"
1'26" 9'26"
90/70 307
267 68
33
98 104 115
177
62
34
12"03"
1'01"
13'04"
110/100 374
325
68
33
115
130 127
205
84 53 23'25" 0'36" 24'01"
ICE1006W
Ambients
Refrigeration Pressures PSIG
Compressor Temps
°F Cycle
Times
°F
Discharge Suction Discharge
Suction
Minutes'
Seconds"
Air/Water
Start
End
Start Freeze
End Freeze
Start
Harv
End
Harv Start End Start End Freeze Harvest Complete
70/50 249
244 58
27
69
66 108
163
44
23
8'34"
2'32"
11'06"
90/70 256
250 59
29
70
77 110
168
48
30
9'31"
1'39"
11'10"
110/100 320
289
75
28
98
110 117
192
68 42 15'55" 1'06" 17'01"